4.95 based on 202 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

HCS01.1E-W0009-A-02-B-ET-EC-CN-L3-NN-FW Bosch Rexroth Indramat

MPN: R911342335

No Tariffs On US Orders
  • Rated 4.6 (49 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Current response time:
6 Minutes 21 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-B-ET-EC-CN-L3-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface, CANopen support, and encoder interfaces for IndraDyn Hiperface and EnDat 2.1/2.2. The controller has a peak current of 9 Amps, operates on 3-phase AC voltage from 110 to 230 Volts, and uses internal air cooling through an integrated blower.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0009-A-02-B-ET-EC-CN-L3-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat and assigned to the HCS IndraDrive Controllers series. In an automation cell, this compact unit converts incoming three-phase power into controlled output for servo axes. It supervises torque and speed for packaging, handling, and processing equipment while supporting coordinated motion through its integrated control interfaces. This arrangement allows the drive to regulate motor behavior closely during starts, stops, and speed changes.

The controller communicates with higher-level PLCs over MultiEthernet, allowing access through PROFINET, EtherNet/IP, or EtherCAT without separate option cards. For servo feedback, it provides an IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface that supplies position data to the internal control loops. A second interface supports CANopen communication for decentralized I/O or axis synchronization. Integrated safety is provided through STO (Safe Torque Off), which removes motor-energizing pulses when the safety input is activated. During dynamic operation, the power module can deliver up to 9 A of peak current for short acceleration demands within its thermal capacity. That combination supports both real-time motion control and integration with peripheral devices on the same machine.

The attached control section is the BASIC variant and is matched to the power stage for this controller version. It operates from a three-phase supply of 3 x AC 110…230 V ±10% and is categorized for infeeding or feeder operation, so regeneration and DC-bus sharing can be handled through external cabinet modules. Heat is removed by internal air cooling through an integrated blower, which moves air across the heat sink without requiring an external fan assembly. The housing has an IP20 rating and is intended for installation in a closed enclosure to protect it from conductive dust. The enclosure design relies on cabinet-level protection rather than open installation on the machine frame.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
9 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
CANopen
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0009A02BETECCNL3NNFW
  • HCS01 1E W0009 A 02 B ET EC CN L3 NN FW
  • hcs01.1e-w0008-a-03-b-et-ec-ep-nn-nn-fw
  • HCS1.1E-W0009-A-02-B-ET-EC-CN-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0009-A-02-B-ET-EC-CN-L3-NN-FW:

Q: What is the peak current capacity of the HCS01.1E-W0009-A-02-B-ET-EC-CN-L3-NN-FW controller?

A: This model can deliver a device peak current of 9 A during operation.

Q: What type of communication interface does the HCS01.1E-W0009-A-02-B-ET-EC-CN-L3-NN-FW provide?

A: The integrated MultiEthernet communication interface allows versatile network connectivity.

Q: How is the HCS01.1E-W0009-A-02-B-ET-EC-CN-L3-NN-FW drive controller cooled?

A: Cooling is achieved by an internal air system using an integrated blower.

Q: What is the IP rating of the HCS01.1E-W0009-A-02-B-ET-EC-CN-L3-NN-FW?

A: The controller supports an IP20 rating, suitable for protected environments.

Q: What mains voltage range is supported by the HCS01.1E-W0009-A-02-B-ET-EC-CN-L3-NN-FW drive controller?

A: It operates with a mains voltage of 3 x AC 110 to 230 V with a ±10% tolerance.


Internal Product Review

  • ‘‘The HCS01.1E-W0009-A-02-B-ET-EC-CN-L3-NN-FW is an HCS drive controller configured with MultiEthernet communication and CANopen support. Operation on 3 x AC 110...230 V ±10% and a 9 A peak current make the unit a strong fit for responsive IndraDrive applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo