4.95 based on 202 reviews

🙶 Easy to navigate website and quick responses from support. Additionally, pretty fast shipping. Our mainte... 🙷

HCS01.1E-W0009-A-02-A-ET-EC-NN-L3-NN-FW Bosch Rexroth Indramat

MPN: R911375293

No Tariffs On US Orders
  • Rated 4.4 (26 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-A-ET-EC-NN-L3-NN-FW is part of the HCS IndraDrive Controllers series and is an HCS drive controller. It features a MultiEthernet communication interface, device peak current of 9 Amps, and operates on a mains voltage of 3 x AC 110 to 230 Volts. The controller includes an integrated blower for air cooling, has an IP20 rating, and supports an encoder interface with IndraDyn Hiperface and EnDat 2.1/2.2.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0009-A-02-A-ET-EC-NN-L3-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. As a compact infeed and axis module, it supplies regulated power to servo and induction motors while exchanging process data with higher-level PLCs. In automated equipment, the unit serves as the power stage of the drive system, carrying out commanded speed and torque changes for packaging, handling, and assembly axes. Its compact layout supports installation in control cabinets where power conversion and networked motion control are combined in one drive platform.

The controller operates from a three-phase supply of 3 x AC 110 to 230 V ±10%, which allows use on low-voltage factory mains. It can deliver a device peak current of 9 A, so short acceleration demand can be handled without requiring a larger frame. Heat is removed by internal blower cooling, which pulls cabinet air through the heat sink. The enclosure has an IP20 rating, so it is protected against finger contact with live parts but not against water entry. Control and diagnostic data are exchanged through MultiEthernet, which supports common industrial Ethernet networks. Safe shutdown of motor torque is provided by STO (Safe Torque Off).

Motor feedback is connected through a universal encoder interface for IndraDyn Hiperface or EnDat 2.1/2.2 encoders, allowing the drive to process absolute position signals without a separate converter. The integrated power section supports infeeding or fed operation, so the unit can receive DC bus energy from an upstream supply or serve as the infeed when used with a suitable braking resistor. The controller is Design Version 1, which identifies the design revision used for this model. This arrangement lets the unit fit into IndraDrive systems that combine power conversion, feedback processing, safety, and real-time network communication in one compact housing.

Communication Interface
MultiEthernet
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
9 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0009A02AETECNNL3NNFW
  • HCS01 1E W0009 A 02 A ET EC NN L3 NN FW
  • hcs01.1e-w0008-a-03-b-et-ec-ep-l4-nn-aw
  • HCS1.1E-W0009-A-02-A-ET-EC-NN-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0009-A-02-A-ET-EC-NN-L3-NN-FW:

Q: What type of communication interface is available on the HCS01.1E-W0009-A-02-A-ET-EC-NN-L3-NN-FW?

A: This controller uses a MultiEthernet communication interface for flexible network connectivity.

Q: How is the HCS01.1E-W0009-A-02-A-ET-EC-NN-L3-NN-FW drive controller cooled?

A: The cooling method employed is air cooling through an integrated blower inside the unit.

Q: What is the peak device current for the HCS01.1E-W0009-A-02-A-ET-EC-NN-L3-NN-FW drive controller?

A: The HCS01.1E-W0009-A-02-A-ET-EC-NN-L3-NN-FW supports a peak device current of 9 A.

Q: What are the mains voltage requirements for the HCS01.1E-W0009-A-02-A-ET-EC-NN-L3-NN-FW?

A: This model operates with a mains voltage input range of 3 x AC 110 to 230 V plus or minus 10%.

Q: What type of safety interface does the HCS01.1E-W0009-A-02-A-ET-EC-NN-L3-NN-FW include?

A: The safety interface provided is STO (Safe Torque Off), offering an important safety function for connected motors.


Internal Product Review

  • ‘‘The HCS01.1E-W0009-A-02-A-ET-EC-NN-L3-NN-FW is an HCS drive controller with MultiEthernet communication and internal blower cooling. Support for 3 x AC 110...230 V ±10% and 9 A peak current gives the unit solid flexibility in drive applications. STO safety and IP20 protection make this controller a strong choice for controlled industrial installations.’’