The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-A-ET-EC-DA-NN-NN-FW is part of the HCS IndraDrive Controllers series and features a MultiEthernet communication interface. This HCS drive controller supports a peak current of 9 Amps, operates at 3-phase AC 110 to 230 Volts, and has an IP20 rating. It uses internal air cooling with an integrated blower and is paired with Control Section Design BASIC (B).

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0009-A-02-A-ET-EC-DA-NN-NN-FW is a compact drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It conditions three-phase input power and performs current-loop control for a single axis while exchanging status data with the plant PLC. By combining the power stage, logic, and communication hardware in one housing, the unit helps reduce cabinet wiring in material-handling, packaging, and assembly equipment. Its compact layout supports coordinated motion where one drive must manage both motor control and network communication within a limited panel footprint.

Internally, the power stage delivers a device peak current of 9 A, supplying short bursts of motor torque during rapid indexing or deceleration. The input accepts 3 × AC 110…230 V ±10%, so one model can operate on common low-voltage three-phase power systems. Heat is removed by internal air cooling through an integrated blower, which avoids external ductwork but still requires unobstructed cabinet airflow. Protection is rated IP20, so live parts are finger-safe, but the controller still requires installation inside an enclosure to keep dust and moisture away.

System integration includes a MultiEthernet port that supports EtherNet/IP, PROFINET, and EtherCAT without hardware changes, which simplifies connection to different control platforms. Motor feedback is handled through the IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, allowing absolute position capture and single-cable motor connection with compatible components. The unit is supplied as Design Version 1 and is classified as infeeding / fed, so it can serve as a DC-bus supply or operate as a consumer in a shared energy system. It is paired with control section design BASIC (B), and safe torque off must be provided externally when required by the machine standard.

Communication Interface
MultiEthernet
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
9 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0009A02AETECDANNNNFW
  • HCS01 1E W0009 A 02 A ET EC DA NN NN FW
  • hcs01.1e-w0008-a-03-b-et-ec-em-sb-nn-fw
  • HCS1.1E-W0009-A-02-A-ET-EC-DA-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0009-A-02-A-ET-EC-DA-NN-NN-FW:

Q: What mains voltage range does the HCS01.1E-W0009-A-02-A-ET-EC-DA-NN-NN-FW controller support?

A: The HCS01.1E-W0009-A-02-A-ET-EC-DA-NN-NN-FW drive controller supports a mains voltage of 3 x AC 110 to 230 V ±10%.

Q: Which communication interface does the HCS01.1E-W0009-A-02-A-ET-EC-DA-NN-NN-FW use?

A: This model features MultiEthernet for its communication interface, allowing flexible network connectivity.

Q: What encoder interfaces are available on the HCS01.1E-W0009-A-02-A-ET-EC-DA-NN-NN-FW?

A: The HCS01.1E-W0009-A-02-A-ET-EC-DA-NN-NN-FW supports encoder interfaces including IndraDyn Hiperface and EnDat 2.1/2.2.

Q: What is the peak current output for the HCS01.1E-W0009-A-02-A-ET-EC-DA-NN-NN-FW?

A: The device provides a peak current output of 9 A for demanding operational cycles.

Q: What cooling method is used in the HCS01.1E-W0009-A-02-A-ET-EC-DA-NN-NN-FW drive controller?

A: This controller uses internal air cooling through an integrated blower for thermal management.


Internal Product Review

  • ‘‘The HCS01.1E-W0009-A-02-A-ET-EC-DA-NN-NN-FW is an HCS drive controller with MultiEthernet communication. Integrated blower cooling and IP20 protection support clean cabinet integration and steady operating performance. A 9 A peak current and 3 x AC 110...230 V input range make this controller a very capable choice for flexible drive applications.’’