HCS01.1E-W0009-A-02-A-CC-EC-PB-NN-NN-FW Bosch Rexroth Indramat

MPN: R911339890

No Tariffs On US Orders
  • Rated 4.5 (40 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-A-CC-EC-PB-NN-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller features a peak device current of 9 Amps and operates on a mains voltage of 3 x AC 110 to 230 Volts. It has SERCOS III master and PROFIBUS communication interfaces and uses internal air cooling with an integrated blower.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0009-A-02-A-CC-EC-PB-NN-NN-FW drive controller is manufactured by Bosch Rexroth Indramat as part of the HCS IndraDrive Controllers series. It belongs to the HCS01 line and functions as a compact inverter stage for servo and induction motors, delivering regulated three-phase power to axes in automated machinery. By coordinating motion through fieldbus links, the unit supports accurate positioning and repeatable cycle control in assembly, packaging, and material-handling equipment. Its compact format also suits control cabinets where axis density and organized wiring are important.

It draws from 3 x AC 110–230 V ±10% mains and can deliver up to 9 A of peak output current to the connected motor. Heat generated during operation is removed through internal air cooling, which uses an integrated blower and allows an enclosure rating of IP20 without external ducts. For real-time coordination, the power section exchanges telegrams over SERCOS III, while a dedicated connector supports PROFIBUS for integration with existing PLC-based systems. The unit is built to design version 1 and does not include a dedicated safety interface, so any required safety functions must be handled by other system components.

The specified control section is the ADVANCED variant, which supports drive-based logic functions and parameter groups that rely on a modular card structure. Feedback from synchronous motors is handled through the IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, maintaining absolute position information for cyclic closed-loop control from startup. DC-link power is supplied through an external infeeding arrangement rather than an internal rectifier, so the controller must be used with a compatible external supply module. This arrangement separates the drive axis from the front-end power stage and fits systems that use a shared DC bus across multiple motion components.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
9 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
PROFIBUS
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0009A02ACCECPBNNNNFW
  • HCS01 1E W0009 A 02 A CC EC PB NN NN FW
  • hcs01.1e-w0008-a-03-b-et-ec-em-nn-nn-fw
  • HCS1.1E-W0009-A-02-A-CC-EC-PB-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0009-A-02-A-CC-EC-PB-NN-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0009-A-02-A-CC-EC-PB-NN-NN-FW drive controller?

A: This controller supports SERCOS III master communication for cross communication interface.

Q: How is the HCS01.1E-W0009-A-02-A-CC-EC-PB-NN-NN-FW kept cool during operation?

A: The cooling method is air, utilizing an internal integrated blower.

Q: What is the peak current capability of the HCS01.1E-W0009-A-02-A-CC-EC-PB-NN-NN-FW?

A: The device has a peak current rating of 9 A.

Q: What mains voltage range is required for the HCS01.1E-W0009-A-02-A-CC-EC-PB-NN-NN-FW drive controller?

A: This drive controller can operate with a mains supply of 3 x AC 110 to 230 V with a tolerance of plus or minus 10%.

Q: What level of ingress protection does the HCS01.1E-W0009-A-02-A-CC-EC-PB-NN-NN-FW provide?

A: The IP rating of this product is IP20, which indicates protection against solid objects greater than 12.5 mm.


Internal Product Review

  • ‘‘The HCS01.1E-W0009-A-02-A-CC-EC-PB-NN-NN-FW is an HCS drive controller with internal air cooling for efficient cabinet integration. SERCOS III master cross communication and a PROFIBUS interface give the platform strong connectivity for coordinated motion applications. A 9 A peak current rating and IP20 protection make the unit a capable choice for industrial drive systems.’’