4.95 based on 202 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

HCS01.1E-W0009-A-02-A-CC-EC-PB-L4-NN-FW Bosch Rexroth Indramat

MPN: R911346412

No Tariffs On US Orders
  • Rated 4.4 (50 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-A-CC-EC-PB-L4-NN-FW is part of the HCS IndraDrive Controllers series and features an internal air cooling method with an integrated blower. This drive controller supports 9 A peak current, 3 x AC 110 to 230 V mains voltage, and has safety interfaces for Safe Torque Off and Safe Brake Control. It is equipped with SERCOS III and PROFIBUS communication interfaces.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0009-A-02-A-CC-EC-PB-L4-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. Installed in multi-axis production cells, it supplies regulated power to motors and exchanges real-time motion data with a higher-level PLC, forming the core of closed-loop automation. This role allows the unit to manage coordinated axis movement in equipment that depends on synchronized speed, torque, and position control. Because the controller closes the drive loop locally, the connected machine can respond quickly to command changes and load variations during repeated operating cycles.

This controller communicates with neighboring drives over the SERCOS III master bus, allowing cross-communication that reduces fieldbus traffic. The control section uses the ADVANCED version, which corresponds to design version 1 for this model. Thermal management relies on internal air cooling through an integrated blower, so no external heat sink is required. A device peak current of 9 A indicates the short-term output available during acceleration. The unit accepts a three-phase supply of 3 × AC 110 to 230 V ±10%, making it suitable for low-voltage factory grids. It uses an infeeding/feeded power supply arrangement that allows energy exchange between connected axes. Its compact electrical layout supports use in cabinet-based systems where several axes share a common power structure.

The encoder feedback port supports Encoder IndraDyn Hiperface/EnDat 2.1/2.2, enabling high-resolution absolute position data from compatible motors. A second fieldbus slot carries PROFIBUS telegrams for integration with installed plant networks. The enclosure has an IP20 rating, so the unit is intended for installation inside a control cabinet. Safety is handled through the dual-channel interface for STO (Safe Torque Off) and SBC (Safe Brake Control), which supports safe stop functions without separate safety contactors. The separate feedback and network interfaces support both precise motor control and communication with installed automation hardware.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
9 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
PROFIBUS
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
  • HCS011EW0009A02ACCECPBL4NNFW
  • HCS01 1E W0009 A 02 A CC EC PB L4 NN FW
  • hcs01.1e-w0008-a-03-b-et-ec-em-l4-nn-fw
  • HCS1.1E-W0009-A-02-A-CC-EC-PB-L4-NN-FW

Frequently Asked Questions about HCS01.1E-W0009-A-02-A-CC-EC-PB-L4-NN-FW:

Q: How is the HCS01.1E-W0009-A-02-A-CC-EC-PB-L4-NN-FW drive controller cooled?

A: The HCS01.1E-W0009-A-02-A-CC-EC-PB-L4-NN-FW is equipped with internal air cooling using an integrated blower.

Q: What is the device peak current for the HCS01.1E-W0009-A-02-A-CC-EC-PB-L4-NN-FW?

A: This drive controller operates with a peak current of 9 A for demanding applications.

Q: What mains voltage range does the HCS01.1E-W0009-A-02-A-CC-EC-PB-L4-NN-FW support?

A: The HCS01.1E-W0009-A-02-A-CC-EC-PB-L4-NN-FW supports a mains supply voltage of three-phase AC 110 to 230 V ±10%.

Q: What primary communication interface is available on the HCS01.1E-W0009-A-02-A-CC-EC-PB-L4-NN-FW?

A: SERCOS III master with cross communication is the primary communication interface for this controller.

Q: Which safety features are integrated in the HCS01.1E-W0009-A-02-A-CC-EC-PB-L4-NN-FW?

A: The safety features include STO (Safe Torque Off) and SBC (Safe Brake Control) functions for operational reliability.


Internal Product Review

  • ‘‘The HCS01.1E-W0009-A-02-A-CC-EC-PB-L4-NN-FW is an HCS Drive Controller featuring an ADVANCED control section and 3 x AC 110...230 V input capability. SERCOS III master cross communication and STO/Safe Brake Control support dependable integration and safe operation, making this unit a strong choice for demanding IndraDrive applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo