HCS01.1E-W0009-A-02-A-CC-EC-EM-S4-NN-FW Bosch Rexroth Indramat
MPN: R911383800
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-A-CC-EC-EM-S4-NN-FW is part of the HCS IndraDrive Controllers series, designed with an ADVANCED control section and a device peak current of 9 Amps. This drive controller uses air cooling through an integrated blower and is rated IP20. It features a SERCOS III master for cross communication and supports IndraDyn Hiperface or EnDat encoder interfaces.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0009-A-02-A-CC-EC-EM-S4-NN-FW is a drive controller built by Bosch Rexroth Indramat and positioned within the HCS IndraDrive Controllers series. It belongs to the compact HCS01 line and functions as the power and control core for servo axes in automated machinery. By converting three-phase mains power into regulated motor currents while coordinating motion profiles, the unit provides closed-loop control of rotary or linear servo motors in production, packaging, or material-handling stations.
The controller exchanges cyclic setpoints and status with upper-level PLCs through a SERCOS III master (cross communication) interface, allowing deterministic, millisecond-level timing across multiple drives. Its first feedback channel accepts Encoder IndraDyn Hiperface/EnDat 2.1/2.2 signals, so absolute position data can be transferred on a single hybrid cable. Peak output is limited to 9 A, which is the maximum phase current available to a connected motor during acceleration or braking events. Internal thermal management is provided by internal air cooling through an integrated blower, eliminating the need for external ducting inside the cabinet. The power stage operates from a supply of 3 x AC 110...230 V ±10%, covering common low-voltage power networks.
Control functions reside on a plug-in section classified as ADVANCED, and the mechanical pairing note indicates that only this design type fits the base power module. A second feedback port provides Encoder emulation, so legacy controllers can read incremental signals generated from the same motor encoder. Cabinet integration is simplified by the housing’s IP20 rating and by the infeeding and fed power topology that lets the device share a common DC bus with companion drives. The unit is design version 1, and no supplemental design options are listed.
Frequently Asked Questions about HCS01.1E-W0009-A-02-A-CC-EC-EM-S4-NN-FW:
Q: What communication interface does the HCS01.1E-W0009-A-02-A-CC-EC-EM-S4-NN-FW use?
A: The HCS01.1E-W0009-A-02-A-CC-EC-EM-S4-NN-FW controller uses SERCOS III master with cross communication for its main communication interface.
Q: How is the HCS01.1E-W0009-A-02-A-CC-EC-EM-S4-NN-FW cooled?
A: This model integrates an internal blower for air cooling.
Q: What is the supported mains voltage for the HCS01.1E-W0009-A-02-A-CC-EC-EM-S4-NN-FW?
A: The device supports a mains voltage range of 3 x AC 110 to 230 V ±10%.
Q: What is the device peak current of the HCS01.1E-W0009-A-02-A-CC-EC-EM-S4-NN-FW controller?
A: The HCS01.1E-W0009-A-02-A-CC-EC-EM-S4-NN-FW offers a device peak current of 9 A.
Q: What types of encoder interfaces are available on the HCS01.1E-W0009-A-02-A-CC-EC-EM-S4-NN-FW?
A: This controller provides encoder support via IndraDyn Hiperface/EnDat 2.1/2.2 on Interface 1 and encoder emulation on Interface 2.