The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a peak current of 9 Amps and supports mains voltages of 3 x AC 110 to 230 Volts. This ADVANCED design controller has SERCOS III master communication, air cooling with an internal blower, and an IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW is a drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It links line power to servo or asynchronous motors and executes speed, torque, and position commands required for automated production cells. The hardware mounts inside a control cabinet and pairs with its control section to form a complete axis package for compact machines and handling equipment. This arrangement lets a single cabinet-mounted unit manage power conversion and closed-loop motion functions in a compact footprint.

It accepts a three-phase supply of 3 x AC 110 to 230 V ±10%, allowing direct connection to factory low-voltage grids without an isolation transformer. The power stage furnishes a peak output of 9 A, which covers the transient current demand of small IndraDyn actuators during acceleration. Thermal management relies on internal air cooling through an integrated blower, and the built-in fan moves cabinet air across the heat sink without external ducting. The housing carries an IP20 ingress rating, so it must be installed in an enclosed panel to prevent contact with live parts. Motion and diagnostic data are exchanged over a SERCOS III master with cross communication link, enabling deterministic coordination with neighboring drives in a ring topology.

The control section supplied is coded ADVANCED, offering extended motion functions and an internal bus that supports parameter access through the power module. For functional safety, it integrates STO (Safe Torque Off), which disables the IGBTs without disturbing fieldbus communication. Encoder feedback is handled by two dedicated ports: the first processes IndraDyn Hiperface/EnDat 2.1/2.2 encoder signals, while the second outputs encoder emulation pulses for legacy position controllers. This arrangement supports machine layouts that need native motor feedback at the drive and a replicated position signal for external equipment. The drive uses a shared DC-bus concept for infeeding and fed operation, allowing regenerated energy to circulate between connected axes.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
9 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0009A02ACCECEML3NNFW
  • HCS01 1E W0009 A 02 A CC EC EM L3 NN FW
  • hcs01.1e-w0008-a-03-b-et-ec-da-nn-nn-fw
  • HCS1.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW controller?

A: The HCS01.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW supports a SERCOS III master communication interface with cross communication capabilities.

Q: How is the HCS01.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW cooled during operation?

A: This controller uses an internal air cooling method with an integrated blower for thermal management.

Q: What is the peak current output for the HCS01.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW?

A: The device is designed with a peak current rating of 9 A.

Q: Which safety feature is included in the HCS01.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW drive controller?

A: The HCS01.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW is equipped with an STO (Safe Torque Off) safety interface.

Q: What mains voltage range does the HCS01.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW support?

A: It operates at a mains voltage of 3 x AC 110...230 V with a tolerance of ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW is an HCS drive controller with an ADVANCED control section design and internal air cooling through an integrated blower. SERCOS III master cross communication and encoder support for IndraDyn Hiperface or EnDat 2.1/2.2 make the controller well suited for precise coordinated motion tasks. IP20 protection and STO functionality provide strong cabinet-ready integration and a valuable safety advantage.’’