HCS01.1E-W0009-A-02-A-CC-EC-EC-NN-NN-FW Bosch Rexroth Indramat
MPN: R911336677
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-A-CC-EC-EC-NN-NN-FW is an HCS IndraDrive Controller with a peak current of 9 Amps and internal air cooling through an integrated blower. It features SERCOS III master cross communication, has two encoder interfaces supporting IndraDyn Hiperface or EnDat 2.1/2.2, and is rated at IP20 protection. This controller is part of the HCS01 line and operates on 3-phase AC voltage from 110 to 230 Volts.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0009-A-02-A-CC-EC-EC-NN-NN-FW is a compact drive controller produced by Bosch Rexroth Indramat as part of the HCS IndraDrive Controllers series. It is intended for servo-axis coordination in packaging, printing, and material-handling lines, where it processes motion commands and modulates motor current in real time to keep position and speed within commanded limits. Its compact format suits cabinet installations where space is limited and multiple axes must be arranged closely. This role makes it suitable for coordinated motion tasks that need stable response during repeated starts, stops, and speed changes.
The controller operates from a three-phase supply of 3 x AC 110...230 V ±10%, making it suitable for low-voltage control cabinets. Heat generated by the power stage is removed by internal air cooling through an integrated blower, so external ducting is not required. The enclosure has an IP20 rating, which means the unit must be mounted inside a protected panel and kept away from conductive dust. The power stage can deliver up to 9 A of peak output current, covering small-frame IndraDyn and compatible third-party servo motors. Real-time command and status data move over the integrated SERCOS III master with cross communication interface, allowing deterministic network cycles and direct drive-to-drive data exchange. Because the unit is not equipped with an internal safety interface, external safety hardware is required when the application calls for it.
The control section uses the ADVANCED variant, which provides additional processing resources for more complex motion functions. Dual feedback sockets accept IndraDyn Hiperface and EnDat 2.1/2.2 encoder signals, letting the controller process motor position data without extra converters. The DC bus supports infeeding and regenerative energy return, so the unit can draw power from a shared supply and send braking energy back into the cabinet power structure when the system is arranged for it. This model is Design Version 1, matching the mechanical and electrical layout used in the HCS01 line. Separate feedback handling also supports integration with different compatible motor families.
Frequently Asked Questions about HCS01.1E-W0009-A-02-A-CC-EC-EC-NN-NN-FW:
Q: What communication interface does the HCS01.1E-W0009-A-02-A-CC-EC-EC-NN-NN-FW support?
A: The HCS01.1E-W0009-A-02-A-CC-EC-EC-NN-NN-FW features a SERCOS III master interface for cross communication.
Q: What types of encoder interfaces are available on the HCS01.1E-W0009-A-02-A-CC-EC-EC-NN-NN-FW?
A: This drive controller provides two encoder interfaces, each supporting IndraDyn Hiperface and EnDat 2.1/2.2 protocols.
Q: What cooling method is used in the HCS01.1E-W0009-A-02-A-CC-EC-EC-NN-NN-FW?
A: Cooling is achieved by an internal air system with an integrated blower built into this model.
Q: What is the maximum peak current supported by the HCS01.1E-W0009-A-02-A-CC-EC-EC-NN-NN-FW?
A: The device can handle a peak current of 9 A during operation.
Q: What mains voltage input is required for the HCS01.1E-W0009-A-02-A-CC-EC-EC-NN-NN-FW?
A: The main voltage supported is 3 x AC 110 to 230 V with a ±10% tolerance.