4.95 based on 202 reviews

🙶 I have always received exceptional service and support in my many years of working with Wake Industrial. 🙷

HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW Bosch Rexroth Indramat

MPN: R911328445

No Tariffs On US Orders
  • Rated 4.6 (57 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW is part of the HCS IndraDrive Controllers series. It features a SERCOS III communication interface and an ECONOMY control section design. This drive controller has a device peak current of 8 Amps, uses air cooling with an integrated blower, and has an IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. The unit provides axis control, current regulation, and diagnostic functions for synchronous or asynchronous motors used in automated machinery. Installed in a control cabinet, it exchanges process data with higher-level PLCs and drive peripherals so motion sequences can be synchronized and monitored in real time. This arrangement lets the drive coordinate motor behavior with machine-level commands during normal operation.

At the network level, the controller communicates through the SERCOS III interface, allowing deterministic cyclic data transfer with PLCs and peer drives. Its control section is the ECONOMY variant, meaning the feature set and I/O capacity are arranged for streamlined applications while core motion functions remain available. Thermal management relies on internal air cooling supplied by an integrated blower, which removes heat without external ducting. The unit can deliver a peak output current of 8 A, which is the maximum short-term current available to the motor from the inverter stage. For electrical protection, the housing carries an IP20 rating, so it is intended for enclosed cabinet installation while keeping wiring access straightforward. Power is drawn from three-phase mains between 200–500 V AC, ±10%, allowing the same model to operate across a wide industrial voltage range.

Power is fed to the DC link through an infeeding and feeding supply section, enabling shared intermediate circuits when multiple HCS01 drives are installed in a group. Precise position feedback is accepted on the first encoder channel via IndraDyn Hiperface/EnDat 2.1/2.2, allowing high-resolution motor commutation without external converter modules. The unit is version 1, indicating the first mechanical and electrical release of this HCS01 frame size. Interface slot two and the safety channel are not equipped on this version, so those functions are absent from the base configuration.

Communication Interface
SERCOS III
Control Section Design Type
ECONOMY
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ECONOMY' (E)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0008A03ES3ECNNNNNNFW
  • HCS01 1E W0008 A 03 E S3 EC NN NN NN FW
  • hcs01.1e-w0008-a-03-a-et-ec-nn-nn-nn-fw
  • HCS1.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW:

Q: What communication interface does the HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW controller use?

A: The HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW supports the SERCOS III communication interface for industrial networking.

Q: What is the mains voltage range for the HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW?

A: This controller accommodates mains voltage inputs of 3 x AC 200 to 500 V with a tolerance of ±10%.

Q: How is the HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW cooled?

A: The device uses internal air cooling provided by an integrated blower.

Q: What is the peak current rating of the HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW?

A: The peak output current for this drive controller is 8 A.

Q: What encoder interface options are present on the HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW?

A: It is equipped with an encoder feedback interface supporting IndraDyn Hiperface and EnDat 2.1/2.2 protocols.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW is an HCS drive controller with SERCOS III communication. Internal blower cooling and IP20 protection support dependable cabinet operation in standard industrial environments. Compatibility with 3 x AC 200 to 500 V mains makes this controller a strong fit for IndraDrive installations.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo