4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

HCS01.1E-W0008-A-03-E-S3-EC-NN-L4-AA-FW Bosch Rexroth Indramat

MPN: R911333491

No Tariffs On US Orders
  • Rated 4.6 (50 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Current response time:
6 Minutes 32 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-E-S3-EC-NN-L4-AA-FW is a drive controller from the HCS IndraDrive Controllers series. It features an internal air cooling system with an integrated blower and supports a device peak current of 8 Amps. This model uses a SERCOS III communication interface and provides STO and SBC safety controls.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-E-S3-EC-NN-L4-AA-FW drive controller is produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It belongs to the HCS01 line and acts as a compact axis inverter that converts the plant's three-phase mains into regulated motor power while exchanging real-time motion data with higher-level PLCs. By coordinating torque, speed, and position loops, the unit supports precise automation tasks in packaging, handling, and material-processing equipment. It is intended for cabinet-installed servo axes that require compact drive hardware and real-time communication.

The power stage accepts a supply of 3 x AC 200...500 V ±10%, allowing operation on low- and medium-voltage factory networks. Under transient acceleration, it can deliver a device peak current of 8 A for short duty cycles. Heat is removed by internal air cooling through an integrated blower, so the module does not rely on external cooling hardware. Communication with the automation system is handled by SERCOS III, providing deterministic cyclic data exchange for multi-axis synchronization. An IP20 housing limits installation to control cabinets but permits front access to power and signal connectors. Front access can simplify cable routing in dense cabinet layouts.

This unit is paired with the ECONOMY control section, designated E, and it is identified as design version 1 in the type code. Motor feedback enters through IndraDyn encoder feedback with Hiperface or EnDat 2.1/2.2, while Interface 2 is not equipped. This arrangement supports closed-loop operation with compatible servo motors. Integrated safety circuits supply STO (Safe Torque Off) and SBC (Safe Brake Control), allowing direct wiring of emergency stop chains without external relays. The internal DC bus supports infeed and regenerative power supply, so energy can be shared between axes or returned to the mains during braking.

Communication Interface
SERCOS III
Control Section Design Type
ECONOMY
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Pairing Note
Paired with Control Section Design 'ECONOMY' (E)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
  • HCS011EW0008A03ES3ECNNL4AAFW
  • HCS01 1E W0008 A 03 E S3 EC NN L4 AA FW
  • hcs01.1e-w0008-a-03-a-et-ec-em-nn-nn-fw
  • HCS1.1E-W0008-A-03-E-S3-EC-NN-L4-AA-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-E-S3-EC-NN-L4-AA-FW:

Q: Which communication protocol does the HCS01.1E-W0008-A-03-E-S3-EC-NN-L4-AA-FW use?

A: This model supports SERCOS III as its communication interface for seamless integration with automation networks.

Q: What is the device peak current for the HCS01.1E-W0008-A-03-E-S3-EC-NN-L4-AA-FW controller?

A: The drive controller delivers a peak current of 8 A for short-term high power demands.

Q: How is the HCS01.1E-W0008-A-03-E-S3-EC-NN-L4-AA-FW cooled during operation?

A: Cooling is achieved through an integrated internal blower providing air cooling.

Q: What mains voltage range is supported by the HCS01.1E-W0008-A-03-E-S3-EC-NN-L4-AA-FW?

A: The controller operates at a mains voltage range of 3 x AC 200 to 500 V with ±10% variation.

Q: What safety features are available on the HCS01.1E-W0008-A-03-E-S3-EC-NN-L4-AA-FW drive controller?

A: This device includes STO (Safe Torque Off) and SBC (Safe Brake Control) for safety interface functionality.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-E-S3-EC-NN-L4-AA-FW is an HCS drive controller designed with SERCOS III communication. Internal air cooling and an 8 A peak current support efficient thermal management and capable dynamic response. STO and SBC safety functions make this controller a strong choice for streamlined machine integration.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo