4.95 based on 202 reviews

🙶 Product was as advertised, got the machine back up and running at a fraction of OEM price. Delivered on ti... 🙷

HCS01.1E-W0008-A-03-B-ET-EC-PB-NN-NN-FW Bosch Rexroth Indramat

MPN: R911327324

No Tariffs On US Orders
  • Rated 4.4 (40 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-B-ET-EC-PB-NN-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features MultiEthernet and PROFIBUS communication interfaces, and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2. The controller has an internal air cooling method with a device peak current of 8 Amps and an IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Bosch Rexroth Indramat’s HCS01.1E-W0008-A-03-B-ET-EC-PB-NN-NN-FW belongs to the HCS IndraDrive Controllers series and functions as a compact drive controller for servo and induction axes in automated machinery. By combining the power section with a modular control section, the unit supplies regulated current to connected motors and exchanges status data with higher-level PLCs, forming the motion layer of material-handling lines, packaging cells, and assembly stations. It is intended for cabinet-based installations where compact axis control and integrated communications are required, and a dedicated safety interface is not fitted so external safety relays must supervise the axis.

The power hardware accommodates a three-phase supply of 3 x AC 200…500 V ±10%, letting a single controller operate on global mains without rewiring. During acceleration peaks, the device can deliver up to 8 A to the motor windings, while the integrated overcurrent logic intervenes when this limit is exceeded. Thermal energy is removed by internal air cooling through an integrated blower, so no external ducting is required inside the cabinet. The housing carries an IP20 rating, which provides basic touch protection when the unit is mounted in an enclosure and leaves additional protection to the surrounding cabinet. For plant networking, the power section is factory-wired to a MultiEthernet port, enabling real-time traffic over EtherNet/IP, PROFINET, or EtherCAT without additional option cards and allowing the controller to fit mixed automation platforms.

The attached control section uses the BASIC design in version 1 and is paired to the power section at the factory for consistent operation within the drive assembly. Command feedback is accepted through the IndraDyn Hiperface/EnDat 2.1/2.2 encoder connector, while fieldbus telegrams can also be exchanged over the integrated PROFIBUS interface for legacy cells that still rely on established network layouts. DC link energy is managed by an infeeding and feeding power supply concept that allows common-bus operation with other drives and supports shared energy flow within a coordinated system.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
PROFIBUS
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0008A03BETECPBNNNNFW
  • HCS01 1E W0008 A 03 B ET EC PB NN NN FW
  • hcs01.1e-w0008-a-03-a-et-ec-ec-l3-nn-fw
  • HCS1.1E-W0008-A-03-B-ET-EC-PB-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-B-ET-EC-PB-NN-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0008-A-03-B-ET-EC-PB-NN-NN-FW controller?

A: The HCS01.1E-W0008-A-03-B-ET-EC-PB-NN-NN-FW supports a MultiEthernet communication interface.

Q: How is the HCS01.1E-W0008-A-03-B-ET-EC-PB-NN-NN-FW cooled?

A: This drive controller uses internal air cooling through an integrated blower.

Q: What is the device peak current for the HCS01.1E-W0008-A-03-B-ET-EC-PB-NN-NN-FW?

A: The device has a peak current rating of 8 A, allowing for handling higher load demands during short intervals.

Q: What encoder interface does the HCS01.1E-W0008-A-03-B-ET-EC-PB-NN-NN-FW offer?

A: This unit is equipped with an Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface on Interface 1.

Q: What mains voltage range does the HCS01.1E-W0008-A-03-B-ET-EC-PB-NN-NN-FW support?

A: The HCS01.1E-W0008-A-03-B-ET-EC-PB-NN-NN-FW is rated for a mains voltage of 3 x AC 200...500 V ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-B-ET-EC-PB-NN-NN-FW is an HCS drive controller with a BASIC control section design. MultiEthernet communication and PROFIBUS support give the unit strong integration flexibility in automated drive networks. A 3 x AC 200...500 V ±10% mains range and 8 A peak current make the controller a capable choice for demanding motion applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo