4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW Bosch Rexroth Indramat

MPN: R911372529

No Tariffs On US Orders
  • Rated 4.5 (28 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Current response time:
3 Minutes 33 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW is part of the HCS IndraDrive Controllers series and utilizes a MultiEthernet communication interface. This HCS Drive Controller features an internal air cooling method with an integrated blower and supports an encoder interface for IndraDyn Hiperface and EnDat 2.1/2.2. It is rated for a peak current of 8 Amps and operates at a mains voltage of 3 x AC 200 to 500 Volts with an IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW is a drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It coordinates power conversion and axis regulation for synchronous and asynchronous motors used in industrial automation cells, conveyors, and assembly lines. Positioned between the mains supply and the motor feedback loop, the unit executes torque, speed, and position commands issued by higher-level PLCs. This arrangement lets a connected axis respond to commanded motion while maintaining stable control during starting, running, and stopping.

The power stage is designed for a three-phase supply of 3 x AC 200 to 500 V ±10%, allowing facilities with either 230 V or 460 V networks to use the same hardware. Under dynamic loading, it can source up to 8 A of peak current, covering low-power servo axes and auxiliary actuators. Internal thermal management is handled by internal air cooling with an integrated blower, so only cabinet airflow needs to be considered during panel layout. The housing carries an IP20 rating, meaning live parts require mounting inside a protected enclosure but no additional gasketing. For controller networking, the device presents a MultiEthernet interface, bringing Ethernet/IP, EtherCAT, and PROFINET access onto a single port without separate option cards. Interface 2 is not equipped on this model, which helps keep the housing width to 50 mm.

This version belongs to the HCS01 line and is design version 1. The control section supplied with the power module is the BASIC variant, and the pairing note indicates that the control and power sections are matched for use together. Position feedback from the motor is accepted through an IndraDyn Hiperface/EnDat 2.1/2.2 encoder connection on the front panel, giving the controller access to rotor position data. The power supply topology is infeeding/fed operation, allowing the device to operate as an energy source or share a common DC bus.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0008A03BETECNNS5NNFW
  • HCS01 1E W0008 A 03 B ET EC NN S5 NN FW
  • hcs01.1e-w0008-a-03-a-cc-ec-nn-s5-nn-fw
  • HCS1.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW use?

A: The HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW supports MultiEthernet communication for flexible network integration.

Q: How is the HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW cooled?

A: This drive controller utilizes air cooling with an integrated blower, providing efficient internal temperature management.

Q: What is the device peak current for this model?

A: It has a device peak current of 8 A, supporting applications with moderate current demands.

Q: Which encoder interfaces are supported by the HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW?

A: The controller is compatible with encoder interface types IndraDyn Hiperface and EnDat 2.1/2.2.

Q: What is the IP rating of the HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW drive controller?

A: The HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW has an IP20 rating, providing basic protection against solid objects.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW is a Bosch Rexroth Indramat HCS drive controller with MultiEthernet communication and a BASIC control section design. Internal blower cooling and IP20 protection support dependable cabinet integration in standard industrial installations. An 8 A peak current rating makes the unit a strong choice for compact IndraDrive motion applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo