4.95 based on 202 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-FW Bosch Rexroth Indramat

MPN: R911340077

No Tariffs On US Orders
  • Rated 4.4 (43 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Current response time:
3 Minutes 41 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-FW is part of the HCS IndraDrive Controllers series. This HCS drive controller supports MultiEthernet communication and uses air cooling with an integrated internal blower. It has a device peak current of 8 Amps and an IP20 rating, with an operating voltage range of 3 x AC 200 to 500 Volts plus or minus 10 percent.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-FW drive controller is manufactured by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It is an axis inverter that regulates motor torque and speed in distributed automation cells, linking servomotors to a higher-level PLC through its integrated control electronics. By converting three-phase mains power into controlled outputs, the unit supports precise positioning, energy recovery, and coordinated multi-axis motion. This controller is intended for cabinet-mounted servo applications that require stable closed-loop response during changing loads.

The controller accepts a 3 x AC 200 to 500 V ±10% supply, which covers common industrial power systems. An integrated blower provides internal air cooling, so no external ducting is required. During acceleration peaks, the inverter can deliver 8 A of output current, which helps determine suitable motor matching. The housing has IP20 protection, so it must be installed inside a closed cabinet. Because the enclosure is intended for cabinet use, surrounding equipment must provide the external barrier against accidental contact and contamination. Field networking is handled through MultiEthernet, which supports EtherNet/IP, PROFINET, and EtherCAT for synchronized command exchange.

The controller uses the BASIC control section, and advanced technology options are not included. Motor feedback enters through Interface 1, which accepts IndraDyn Hiperface/EnDat 2.1/2.2 encoder feedback for high-resolution absolute position data. The common DC bus uses an infeeding/feeded power supply unit, allowing energy exchange between axes during operation. The hardware format follows the HCS01 line and uses the 45 mm booksize width common across the range. Interface 2 is unused, and the narrow housing helps the controller fit beside other modules in compact drive assemblies.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0008A03BETECNNS4NNFW
  • HCS01 1E W0008 A 03 B ET EC NN S4 NN FW
  • hcs01.1e-w0008-a-03-a-cc-ec-nn-l4-nn-fw
  • HCS1.1E-W0008-A-03-B-ET-EC-NN-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-FW:

Q: What communication interface is included on the HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-FW drive controller?

A: The HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-FW is equipped with a MultiEthernet communication interface for versatile network connectivity.

Q: What is the device peak current supported by HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-FW?

A: This drive controller offers a device peak current rating of 8 A, enabling it to handle moderate load requirements.

Q: What cooling method does the HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-FW drive controller use?

A: The HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-FW uses an internal air-cooling system through an integrated blower to manage heat.

Q: What mains voltage range is compatible with the HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-FW?

A: This model supports a mains voltage range of 3 x AC 200 to 500 V with a tolerance of ±10%.

Q: What is the IP rating of the HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-FW drive controller?

A: The HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-FW is rated IP20 for ingress protection, meaning it is protected against medium-sized foreign objects.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-FW is an HCS drive controller with MultiEthernet communication, well suited for streamlined networked automation. BASIC control architecture and internal blower cooling give the controller a clean, efficient design for enclosed drive cabinets. An 8 A peak current rating and 3 x AC 200...500 V ±10% input make the controller a strong choice for flexible IndraDrive integration.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo