4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

HCS01.1E-W0008-A-03-B-ET-EC-NN-L3-NN-FW Bosch Rexroth Indramat

MPN: R911335596

No Tariffs On US Orders
  • Rated 4.6 (47 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-B-ET-EC-NN-L3-NN-FW is part of the HCS IndraDrive Controllers series and features a MultiEthernet communication interface. This drive controller supports a device peak current of 8 Amps, provides IP20 protection, and uses an internal air cooling method through an integrated blower. It includes a safety interface with Safe Torque Off and an encoder interface supporting IndraDyn Hiperface and EnDat protocols.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-B-ET-EC-NN-L3-NN-FW is a drive controller produced by Bosch Rexroth Indramat and assigned to the HCS IndraDrive Controllers series. The module forms the power section of a servo axis by converting incoming AC power into regulated DC-link energy and then supplying controlled motor current to rotary or linear actuators. By combining power conversion with axis control, the unit supports deterministic positioning and stable speed regulation in packaging, handling, and assembly systems. It is design version 1 for this power class, indicating the first release of this controller configuration.

The controller operates from a three-phase mains range of 3 x AC 200-500 V ±10%, allowing the same hardware to run on different industrial supply voltages. A peak output of 8 A is available for short acceleration demands before current limiting begins. Internal heat is removed by internal air cooling with an integrated blower, so the unit does not require external cooling ductwork. Network communication is handled through MultiEthernet, which supports multiple real-time Ethernet protocols through one interface. A dedicated safety channel provides STO (Safe Torque Off), which disables torque-producing power to the motor when the safety circuit is opened.

The control section in this unit is the BASIC variant, so optional technology functions are not pre-enabled. Motor feedback enters through Interface 1 by way of an IndraDyn Hiperface and EnDat 2.1/2.2 encoder interface, while Interface 2 is unused and remains open for later expansion. The power stage is configured for infeeding and fed operation, which allows DC-bus energy sharing with adjacent axes and supports power return to the mains during regeneration. Application software is ordered separately rather than supplied on the device. This arrangement keeps the controller matched to the intended axis function without adding unused options to the base unit.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0008A03BETECNNL3NNFW
  • HCS01 1E W0008 A 03 B ET EC NN L3 NN FW
  • hcs01.1e-w0008-a-03-a-cc-ec-em-nn-nn-fw
  • HCS1.1E-W0008-A-03-B-ET-EC-NN-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-B-ET-EC-NN-L3-NN-FW:

Q: What communication interface does the HCS01.1E-W0008-A-03-B-ET-EC-NN-L3-NN-FW support?

A: The HCS01.1E-W0008-A-03-B-ET-EC-NN-L3-NN-FW offers MultiEthernet connectivity as its communication interface.

Q: Which encoder interface types are provided by this IndraDrive Controller?

A: This drive controller supports encoder feedback via IndraDyn Hiperface and EnDat 2.1/2.2 interfaces.

Q: What is the IP rating of the HCS01.1E-W0008-A-03-B-ET-EC-NN-L3-NN-FW drive controller?

A: The HCS01.1E-W0008-A-03-B-ET-EC-NN-L3-NN-FW has an IP20 rating, offering basic protection against solid objects.

Q: How is the HCS01.1E-W0008-A-03-B-ET-EC-NN-L3-NN-FW drive controller cooled?

A: This unit is cooled internally by air through an integrated blower, improving heat dissipation within the enclosure.

Q: What is the device peak current for this HCS IndraDrive Controller model?

A: The device supports a peak current of 8 A for robust performance under demanding conditions.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-B-ET-EC-NN-L3-NN-FW is a Bosch Rexroth Indramat HCS drive controller with an 8 A peak current rating. MultiEthernet communication and IndraDyn Hiperface/EnDat 2.1/2.2 encoder support give the controller strong integration value in networked motion applications. Internal blower cooling and STO safety functionality make this model a very capable choice for dependable industrial drive control.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo