4.95 based on 202 reviews

🙶 Great response and customer service. Back-order item was shipped sooner than expected as well. 🙷

HCS01.1E-W0008-A-03-B-ET-EC-EP-NN-NN-FW Bosch Rexroth Indramat

MPN: R911374271

No Tariffs On US Orders
  • Rated 4.5 (57 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Current response time:
6 Minutes 15 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-B-ET-EC-EP-NN-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller features a MultiEthernet communication interface and an IP20 rating, with a device peak current of 8 Amps. It has an internal air cooling system using an integrated blower and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-B-ET-EC-EP-NN-NN-FW is a drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It is intended to regulate synchronous and asynchronous motors in automated machinery, providing closed-loop velocity and position control while integrating with upstream PLCs. By combining the power section of the HCS01 line with a BASIC control card, the unit forms a compact axis module that simplifies cabinet layouts in multi-drive installations.

The controller communicates with higher-level networks through a MultiEthernet port, so the same unit can be assigned to EtherNet/IP, PROFINET, or EtherCAT topologies. Its mains input accepts 3 × AC 200–500 V ±10%, allowing the same model to be installed on both 230 V and 480 V factory feeders without a transformer. The control section is classified as BASIC, which means it provides standard motion functions without integrated safety logic. An enclosure rating of IP20 indicates that the device must be mounted inside a protective panel to prevent finger contact and limit dust exposure. Internally, the inverter can deliver a peak output current of 8 A, which is the maximum motor phase current available for acceleration or dynamic braking.

Thermal management is handled by internal air cooling through an integrated blower, so cabinet layouts do not require ducted air or liquid cooling and can follow the 45 °C ambient limit stated for the HCS01 family. Feedback wiring is terminated on an IndraDyn Hiperface/EnDat 2.1/2.2 encoder connector, enabling high-resolution position loops without additional interface cards. The unit is Design 1. Power is managed by an infeeding and fed supply concept, so the unit can share a common DC bus and regenerated energy from one axis can be used by others instead of being dissipated.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0008A03BETECEPNNNNFW
  • HCS01 1E W0008 A 03 B ET EC EP NN NN FW
  • hcs01.1e-w0008-a-03-a-cc-ec-da-nn-nn-fw
  • HCS1.1E-W0008-A-03-B-ET-EC-EP-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-B-ET-EC-EP-NN-NN-FW:

Q: What communication interface does the HCS01.1E-W0008-A-03-B-ET-EC-EP-NN-NN-FW drive controller use?

A: The HCS01.1E-W0008-A-03-B-ET-EC-EP-NN-NN-FW supports MultiEthernet communication for flexible network connectivity.

Q: What is the device peak current of the HCS01.1E-W0008-A-03-B-ET-EC-EP-NN-NN-FW controller?

A: This controller can provide a peak current output of 8 A for short-term demands.

Q: How is the HCS01.1E-W0008-A-03-B-ET-EC-EP-NN-NN-FW drive controller cooled?

A: The cooling method is internal air cooling utilizing an integrated blower.

Q: What mains voltage range does the HCS01.1E-W0008-A-03-B-ET-EC-EP-NN-NN-FW support?

A: The HCS01.1E-W0008-A-03-B-ET-EC-EP-NN-NN-FW operates on 3-phase AC mains voltage from 200 to 500 V with ±10% tolerance.

Q: What encoder interfaces are supported by the HCS01.1E-W0008-A-03-B-ET-EC-EP-NN-NN-FW controller?

A: This model features encoder interface compatibility with IndraDyn Hiperface as well as EnDat 2.1 and 2.2 protocols.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-B-ET-EC-EP-NN-NN-FW is an HCS drive controller with MultiEthernet communication and IP20 protection. Internal blower cooling and 8 A peak current give the unit efficient thermal management and solid dynamic response. The BASIC control section and 3 x AC 200 to 500 V mains range make this model a practical choice for flexible IndraDrive integration.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo