4.95 based on 202 reviews

🙶 a+ fast delivery 🙷

HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW Bosch Rexroth Indramat

MPN: R911378003

No Tariffs On US Orders
  • Rated 4.6 (29 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Current response time:
3 Minutes 14 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW is part of the HCS IndraDrive Controllers series and is designed with BASIC control section type. This HCS Drive Controller features MultiEthernet communication, an IP20 rating, and supports STO and SBC safety interfaces. Its cooling is managed by an integrated blower, and it operates at a peak current of 8 Amps with a mains voltage range of 3 x AC 200 to 500 Volts.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW is a compact drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It governs servo and induction axes by modulating power to the connected motor in response to fieldbus commands. The controller serves as the link between the automation system and the motor power stage, translating motion requests into controlled electrical output. This operating role makes it suitable for packaging, handling, and assembly cells that require accurate axis response during automated motion.

This unit communicates over MultiEthernet, allowing simultaneous access from EtherNet/IP, PROFINET, or EtherCAT masters without additional option cards. A peak phase output of 8 A supports small-to-medium actuators during acceleration bursts, while the mains connection accepts 3 x AC 200…500 V ±10% for use on a wide range of plant supplies. This broad input range allows the same controller type to fit installations with different regional supply levels. Thermal management relies on internal air cooling, where an integrated blower moves cabinet air across the heat sink. The housing carries an IP20 rating, so the unit should be installed inside a control enclosure for protection against dust and moisture.

The control section is classified as BASIC, which is the entry-level logic layer paired with this power section. Feedback from the motor enters through an IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, enabling high-resolution position loops without separate signal converters. This direct feedback path supports stable speed and position control during normal machine operation. Functional safety is handled by integrated STO (Safe Torque Off) and SBC (Safe Brake Control) channels, which remove drive energy and manage an external brake according to the active safety command. The power module supports infeeding and fed operation, so it can return regenerative energy to the DC bus and also draw from that bus when required.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
  • HCS011EW0008A03BETECEPL4NNFW
  • HCS01 1E W0008 A 03 B ET EC EP L4 NN FW
  • hcs01.1e-w0008-a-03-a-cc-ec-cn-nn-nn-fw
  • HCS1.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW controller provide?

A: The HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW supports MultiEthernet for its communication interface, enabling integration with various Ethernet-based fieldbus systems.

Q: How is the HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW drive controller cooled?

A: This drive controller is cooled internally using an integrated blower system with air cooling.

Q: What is the device peak current of the HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW?

A: The peak current for the HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW model is rated at 8 A.

Q: What safety interfaces are included in the HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW controller?

A: This unit offers safety interfaces including STO (Safe Torque Off) and SBC (Safe Brake Control) for secure operation.

Q: What is the supported mains voltage range for the HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW?

A: The HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW supports a mains voltage range of 3 x AC 200 to 500 V with a tolerance of ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW is an HCS drive controller designed for 3 x AC 200 to 500 V ±10% operation. MultiEthernet communication and encoder support for IndraDyn Hiperface or EnDat 2.1/2.2 give the unit strong integration value in motion systems. Internal blower cooling and STO/SBC safety functions make this controller a highly capable choice for safety-conscious automation.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo