HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW Bosch Rexroth Indramat
MPN: R911381647
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
3 Minutes
35 Seconds
The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW is part of the HCS IndraDrive Controllers series and features a MultiEthernet communication interface. This drive controller offers a device peak current of 8 Amps, supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2, and utilizes internal air cooling with an integrated blower. It is rated IP20 and is equipped with an STO safety interface.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW is a compact drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. As a servo inverter for small and medium-power axes, it provides closed-loop regulation of synchronous and asynchronous motors used in packaging, material handling, and assembly stations. The module combines a power section and a replaceable control section in one housing so that machine builders can integrate axis control, fieldbus communication, and functional safety without adding standalone components.
The controller communicates with PLCs through the MultiEthernet interface, enabling EtherNet/IP, PROFINET, or EtherCAT access without extra option cards. It ships with a control section designated BASIC, which supports positioning functions and matches the stated pairing guideline. Thermal management relies on internal air cooling through an integrated blower, so separate cabinet airflow is not required. With an enclosure rating of IP20, the unit is meant for mounting inside a control cabinet free of conductive dust or fluids. The power stage accepts 3 x AC 200 to 500 V ±10% mains and can deliver up to 8 A of peak device current during load changes.
Functional safety is provided by the STO (Safe Torque Off) interface, which removes drive energy without interrupting upstream control logic. Position feedback arrives through IndraDyn Hiperface/EnDat 2.1/2.2 encoder support, allowing absolute encoders to be read through a single connector. The power section operates in infeed/feed mode, so it can draw from or return regenerative energy to a shared DC bus on multi-axis machines. Hardware is locked to design version 1 of the HCS01 line, and no supplementary features are declared. Firmware is supplied separately, and the required release must match the installed control section.
Frequently Asked Questions about HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW:
Q: What communication interface is provided on the HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW drive controller?
A: This model uses MultiEthernet as its communication interface, supporting various Ethernet protocols.
Q: What is the cooling method for the HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW controller?
A: The cooling is managed internally by an integrated blower, providing effective air cooling within the device.
Q: What is the device peak current specification for the HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW?
A: This unit is rated for a maximum peak current of 8 A, suitable for controlled drive applications.
Q: What mains voltage range does the HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW support?
A: The mains voltage required is 3 x AC 200 to 500 V with a tolerance of ±10%.
Q: What type of safety interface is included in the HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW drive controller?
A: The safety interface includes STO (Safe Torque Off) functionality for enhanced operational safety.