4.95 based on 202 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

HCS01.1E-W0008-A-03-B-ET-EC-EP-DA-NN-FW Bosch Rexroth Indramat

MPN: R911396899

No Tariffs On US Orders
  • Rated 4.6 (57 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-B-ET-EC-EP-DA-NN-FW is part of the HCS IndraDrive Controllers series. This HCS drive controller offers a device peak current of 8 Amps and uses air cooling through an integrated blower. It features MultiEthernet communication and an IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Bosch Rexroth Indramat manufactures the HCS01.1E-W0008-A-03-B-ET-EC-EP-DA-NN-FW drive controller for the HCS IndraDrive Controllers series. It combines a power section with a pluggable control section to regulate motor torque, speed, and position in automated machinery. In a multi-axis installation, the unit sits between the plant’s three-phase line supply and connected IndraDyn servomotors, converting PLC commands into controlled current for coordinated motion. This arrangement allows the controller to serve as both the power interface and the motion-control stage for the connected axis.

Incoming power is accepted from a 3 x AC 200–500 V ±10% supply, allowing operation on both low-voltage and standard factory power systems without an external transformer. The power section can deliver a peak phase current of 8 A, which supports small and medium servo axes during short acceleration demands. Thermal management uses internal air cooling through an integrated blower, which moves cabinet air across the heat sink. Because of this cooling method, the enclosure layout should leave clear airflow space around the drive. The housing has an IP20 rating, so the unit is intended for installation inside a protective cabinet. Command and diagnostic data are exchanged over a Multi-Ethernet interface that supports several real-time Ethernet fieldbus options.

Feedback support includes IndraDyn Hiperface/EnDat 2.1/2.2 encoder feedback, allowing the drive to process high-resolution position data directly. Direct encoder compatibility removes the need for external feedback converters and helps keep wiring more compact. The installed control section is the BASIC variant, and this power module is intended to be used only with that matching board. For DC-bus energy exchange, the unit supports infeeding and fed operation, so it can handle power flow in either direction within the drive system. The controller belongs to design Version 1 of this hardware generation.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0008A03BETECEPDANNFW
  • HCS01 1E W0008 A 03 B ET EC EP DA NN FW
  • hcs01.1e-w0006-a-02-e-s3-ec-nn-nn-nn-fw
  • HCS1.1E-W0008-A-03-B-ET-EC-EP-DA-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-B-ET-EC-EP-DA-NN-FW:

Q: What type of communication interface is included on the HCS01.1E-W0008-A-03-B-ET-EC-EP-DA-NN-FW drive controller?

A: The HCS01.1E-W0008-A-03-B-ET-EC-EP-DA-NN-FW controller supports MultiEthernet communication for integration with a wide array of networks.

Q: How is the HCS01.1E-W0008-A-03-B-ET-EC-EP-DA-NN-FW drive controller cooled?

A: This model features internal air cooling through an integrated blower to manage thermal conditions during operation.

Q: What is the peak current supported by the HCS01.1E-W0008-A-03-B-ET-EC-EP-DA-NN-FW controller?

A: The device has a peak current rating of 8 A, making it suitable for moderate power applications.

Q: What type of encoder interface does this controller offer?

A: The HCS01.1E-W0008-A-03-B-ET-EC-EP-DA-NN-FW uses an encoder interface compatible with IndraDyn Hiperface and EnDat 2.1/2.2 protocols.

Q: What is the mains voltage range supported by the HCS01.1E-W0008-A-03-B-ET-EC-EP-DA-NN-FW controller?

A: It supports a mains voltage supply of 3 x AC 200...500 V with a ±10% tolerance.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-B-ET-EC-EP-DA-NN-FW is an HCS drive controller with MultiEthernet communication and a BASIC control section design. Internal blower cooling and IP20 protection support dependable cabinet operation in standard industrial installations. The 8 A peak current rating makes this unit a practical and capable choice for compact IndraDrive motion setups.’’