4.95 based on 202 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

HCS01.1E-W0008-A-03-B-ET-EC-EM-S4-NN-FW Bosch Rexroth Indramat

MPN: R911369163

No Tariffs On US Orders
  • Rated 4.4 (28 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-B-ET-EC-EM-S4-NN-FW is part of the HCS IndraDrive Controllers series and is a drive controller with a device peak current of 8 Amps. This unit supports MultiEthernet communication and is equipped with IP20 protection. It uses air cooling with an integrated blower and provides encoder interfaces, including IndraDyn Hiperface and EnDat 2.1/2.2.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-B-ET-EC-EM-S4-NN-FW is a drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. This unit combines power electronics and a control section to command servo or asynchronous motors in automated equipment. By converting three-phase mains power and issuing precise torque commands, it serves as the actuator interface for packaging machines, pick-and-place stations, and material-handling axes in factory automation lines.

The drive accepts a supply of 3 x AC 200...500 V ±10%, so it can run directly from common industrial feeders on 50 Hz or 60 Hz grids. Thermal management relies on internal air cooling with an integrated blower, and the fan moves air across the heat sink without requiring external ducting. Motor windings are energized through an inverter leg that can source up to 8 A peak, enabling acceleration of small to medium axes. The control electronics use the BASIC configuration, providing standard motion-control functions and parameter storage on detachable memory. An enclosure rating of IP20 indicates touch-safe but non-sealed construction, so the unit must be installed inside a control cabinet.

System connectivity is handled by MultiEthernet, allowing the controller to communicate over EtherNet/IP, PROFINET, and EtherCAT without option cards. For feedback, Interface 1 reads IndraDyn Hiperface and EnDat 2.1/2.2 encoder feedback signals, while Interface 2 provides encoder emulation pulses so external controls can mirror position information. The power stage supports infeeding and fed operation, permitting energy exchange across a shared DC bus during braking or peak demand. Design version 1, the HCS01 line designation, and the pairing with the BASIC control section identify the controller layout used for this variant.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0008A03BETECEMS4NNFW
  • HCS01 1E W0008 A 03 B ET EC EM S4 NN FW
  • hcs01.1e-w0006-a-02-e-s3-ec-nn-l4-nn-fw
  • HCS1.1E-W0008-A-03-B-ET-EC-EM-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-B-ET-EC-EM-S4-NN-FW:

Q: What communication interface does the HCS01.1E-W0008-A-03-B-ET-EC-EM-S4-NN-FW drive controller use?

A: The HCS01.1E-W0008-A-03-B-ET-EC-EM-S4-NN-FW supports MultiEthernet communication interface for connectivity.

Q: What cooling method is used by the HCS01.1E-W0008-A-03-B-ET-EC-EM-S4-NN-FW?

A: This controller is equipped with an internal air cooling system using an integrated blower.

Q: What is the peak current capability of the HCS01.1E-W0008-A-03-B-ET-EC-EM-S4-NN-FW?

A: The device delivers a peak current of 8 A during operation.

Q: What mains voltage range does the HCS01.1E-W0008-A-03-B-ET-EC-EM-S4-NN-FW support?

A: It operates with a mains voltage supply of 3-phase AC 200 to 500 V with a tolerance of ±10%.

Q: What is the IP rating of the HCS01.1E-W0008-A-03-B-ET-EC-EM-S4-NN-FW?

A: This drive controller is rated IP20, providing basic protection against solid objects but no protection from water.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-B-ET-EC-EM-S4-NN-FW is an HCS drive controller that stands out with MultiEthernet communication. Internal blower cooling and an IP20 rating support dependable cabinet operation in standard industrial settings. An 8 A peak current and a 3 x AC 200...500 V ±10% mains range make this controller a strong fit for flexible drive applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo