HCS01.1E-W0008-A-03-B-ET-EC-EM-L3-NN-FW Bosch Rexroth Indramat

MPN: R911342148

No Tariffs On US Orders
  • Rated 4.4 (65 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Current response time:
6 Minutes 53 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-B-ET-EC-EM-L3-NN-FW is part of the HCS IndraDrive Controllers series and operates as an HCS drive controller. It supports MultiEthernet communication, features a BASIC control section design, and has a peak current of 8 Amps. The device uses an internal air cooling system with a built-in blower and is rated IP20 for protection.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-B-ET-EC-EM-L3-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It functions as a compact control and power stage for synchronous or asynchronous motors used in industrial automation. The unit governs torque or speed from real-time feedback while exchanging control data with higher-level PLCs and motion platforms. This makes it suitable for conveyor axes, handling systems, and other machines that need closed-loop motor control from a single cabinet component.

This unit communicates over a MultiEthernet port, allowing direct integration into common industrial networks without additional gateways. It operates from a three-phase supply of 3 × AC 200–500 V ±10% and can deliver up to 8 A of peak current to the connected motor, supporting short acceleration bursts. Thermal management relies on internal air cooling through an integrated blower, so cabinet airflow remains localized within the unit. An enclosure rating of IP20 indicates finger-safe accessibility but requires installation inside a protected electrical cabinet. This arrangement suits cabinet-mounted axes where the surrounding machine enclosure provides the added protection needed for industrial service.

The control section uses the BASIC variant in design version 1 and pairs with the HCS01 line as indicated by the type code. Feedback processing is handled through an Encoder IndraDyn Hiperface/EnDat 2.1/2.2 port, and a secondary channel provides encoder emulation for legacy drives. Power is exchanged with a common DC bus through an Infeeding / Feeded supply concept, which allows energy sharing among multiple axes. Functional safety is handled by the integrated STO interface, which removes torque within the specified reaction time when activated. The encoder emulation channel can also support older supervisory interfaces that expect simulated feedback signals.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0008A03BETECEML3NNFW
  • HCS01 1E W0008 A 03 B ET EC EM L3 NN FW
  • hcs01.1e-w0006-a-02-e-s3-ec-ep-l4-nn-fw
  • HCS1.1E-W0008-A-03-B-ET-EC-EM-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-B-ET-EC-EM-L3-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0008-A-03-B-ET-EC-EM-L3-NN-FW drive controller?

A: The HCS01.1E-W0008-A-03-B-ET-EC-EM-L3-NN-FW features a MultiEthernet communication interface for flexible network integration.

Q: How is the HCS01.1E-W0008-A-03-B-ET-EC-EM-L3-NN-FW drive controller cooled?

A: This controller includes an internal air cooling system through an integrated blower.

Q: What is the peak current supported by the HCS01.1E-W0008-A-03-B-ET-EC-EM-L3-NN-FW controller?

A: The device has a peak current rating of 8 A, defining its transient load handling capability.

Q: What encoder feedback interfaces are available on the HCS01.1E-W0008-A-03-B-ET-EC-EM-L3-NN-FW control section?

A: The controller supports encoder connections with IndraDyn Hiperface and EnDat 2.1/2.2 interfaces.

Q: What built-in safety interface does the HCS01.1E-W0008-A-03-B-ET-EC-EM-L3-NN-FW provide?

A: This model features the STO (Safe Torque Off) safety interface for enhanced operational safety.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-B-ET-EC-EM-L3-NN-FW is an HCS drive controller with MultiEthernet communication that feels well suited for modern motion systems. BASIC control design and an internal blower cooling method support straightforward integration and stable thermal management. An 8 A peak current rating paired with STO safety gives the unit strong technical value.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo