HCS01.1E-W0008-A-03-B-ET-EC-EC-S5-NN-NW Bosch Rexroth Indramat

MPN: R911388279

No Tariffs On US Orders
  • Rated 4.6 (45 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-B-ET-EC-EC-S5-NN-NW is part of the HCS IndraDrive Controllers series and features a MultiEthernet communication interface. This BASIC design drive controller provides a peak current of 8 Amps and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2. It employs an internal air cooling method and has an IP20 rating, operating with a mains voltage range of 200 to 500 Volts AC.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-B-ET-EC-EC-S5-NN-NW is a drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It regulates power flow between an AC mains supply and synchronous or asynchronous motors, enabling speed, torque, and position control in automated machinery and material-handling cells. By combining power electronics with closed-loop feedback interfaces, the unit links programmable logic controllers to the mechanical axis for coordinated motion control.

This controller communicates with supervisory networks over MultiEthernet, so a single hardware port can operate on EtherNet/IP, PROFINET, or other deterministic protocols without extra option cards. The power stage accepts a three-phase input of 3 × AC 200…500 V ±10 %, letting the same hardware serve installations that use 200 V or 480 V utility grids. During acceleration, the integrated IGBT bridge can deliver a peak output of 8 A to the motor windings, and this transient value sets the maximum admissible torque demand from the connected axis. Thermal losses are removed by internal air cooling through an onboard blower, so external cabinet airflow is not required. The IP20 housing limits finger contact with live parts and requires installation in a closed electrical enclosure that provides ambient protection.

The logic layer uses the BASIC control section, giving standard motion functions while keeping parameter sets compatible with higher-feature variants. Both feedback channels support IndraDyn Hiperface/EnDat 2.1/2.2 encoders, allowing dual-loop operation or redundant sensing without adapter boards. The unit is design version 1, which confirms the mechanical dimensions and connector placement used for this model. DC bus energy is managed by the integrated power module rated for infeeding and bus-fed operation, so it can operate as a standalone rectifier or share a common bus with additional drives.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0008A03BETECECS5NNNW
  • HCS01 1E W0008 A 03 B ET EC EC S5 NN NW
  • hcs01.1e-w0006-a-02-b-et-ec-pb-nn-nn-fw
  • HCS1.1E-W0008-A-03-B-ET-EC-EC-S5-NN-NW

Frequently Asked Questions about HCS01.1E-W0008-A-03-B-ET-EC-EC-S5-NN-NW:

Q: What communication interface does the HCS01.1E-W0008-A-03-B-ET-EC-EC-S5-NN-NW drive controller support?

A: The HCS01.1E-W0008-A-03-B-ET-EC-EC-S5-NN-NW supports MultiEthernet for its communication interface.

Q: How is the HCS01.1E-W0008-A-03-B-ET-EC-EC-S5-NN-NW cooled during operation?

A: This unit features internal air cooling with an integrated blower for heat management.

Q: What is the device peak current rating of the HCS01.1E-W0008-A-03-B-ET-EC-EC-S5-NN-NW?

A: The device can achieve a peak current output of 8 A for demanding applications.

Q: What is the IP protection level of the HCS01.1E-W0008-A-03-B-ET-EC-EC-S5-NN-NW?

A: It features an IP20 rating, providing basic protection against solid objects and limited ingress.

Q: What mains voltage range is supported by the HCS01.1E-W0008-A-03-B-ET-EC-EC-S5-NN-NW drive controller?

A: The controller operates with a mains voltage of 3 x AC 200 to 500 V with a ±10% tolerance range.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-B-ET-EC-EC-S5-NN-NW is an HCS drive controller engineered for precise machine integration with MultiEthernet communication and a BASIC control section. Integrated blower cooling and IP20 protection support stable operation in enclosed industrial cabinets. Support for 3 x AC 200...500 V mains makes this unit a strong fit for flexible drive platforms.’’