4.95 based on 202 reviews

🙶 Product was as advertised, got the machine back up and running at a fraction of OEM price. Delivered on ti... 🙷

HCS01.1E-W0008-A-03-B-ET-EC-EC-S4-NN-FW Bosch Rexroth Indramat

MPN: R911344064

No Tariffs On US Orders
  • Rated 4.6 (44 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-B-ET-EC-EC-S4-NN-FW is a drive controller in the HCS IndraDrive Controllers series designed with a MultiEthernet communication interface and an IP20 protection rating. This model features a device peak current of 8 Amps and uses internal air cooling through an integrated blower. It also supports IndraDyn Hiperface and EnDat 2.1/2.2 encoder interfaces.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Bosch Rexroth Indramat markets the HCS01.1E-W0008-A-03-B-ET-EC-EC-S4-NN-FW as part of the HCS IndraDrive Controllers series. The unit is an HCS drive controller intended for multi-axis automation where compact inverter stages must regulate torque, speed, and position on synchronous and asynchronous motors. By combining a control section with a power section in one enclosure, the product reduces cabinet space and simplifies wiring for machine tools, packaging lines, and general material-handling equipment.

The control hardware communicates over MultiEthernet, allowing PLCs that use EtherNet/IP, PROFINET, or EtherCAT to share process data through a single port. Inside the chassis, a BASIC control section provides standard motion functions without optional safety extensions, and this is identified as Version 1 in the type code. Cooling is handled by internal air cooling through an integrated blower, so the blower pulls cabinet air across the heat sink and no external ducting is required. The power stage delivers a device peak current of 8 A, which is enough to handle short-term acceleration demands on low-inertia servo axes. The control section and power module are matched for operation in the same housing.

The housing is rated IP20, so the controller must be installed in an enclosed cabinet. It accepts a wide mains input of 3 × AC 200…500 V ±10%, letting one unit operate on both 230 V and 400 V factory grids. Two identical feedback ports support IndraDyn Hiperface or EnDat 2.1 / 2.2 encoder protocols, enabling redundant position signals or separate motor and external encoder channels. The internal DC link can operate in infeeding or fed mode, so excess regenerative energy may be returned to the plant mains or absorbed by other drives on the bus. This arrangement also allows the controller to manage motor feedback and an additional measuring signal within the same unit.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0008A03BETECECS4NNFW
  • HCS01 1E W0008 A 03 B ET EC EC S4 NN FW
  • hcs01.1e-w0006-a-02-b-et-ec-pb-l4-nn-fw
  • HCS1.1E-W0008-A-03-B-ET-EC-EC-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-B-ET-EC-EC-S4-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0008-A-03-B-ET-EC-EC-S4-NN-FW support?

A: This model features MultiEthernet communication capabilities.

Q: Which cooling method is used in the HCS01.1E-W0008-A-03-B-ET-EC-EC-S4-NN-FW drive controller?

A: Cooling is provided by an integrated internal blower using air.

Q: What is the peak current rating of the HCS01.1E-W0008-A-03-B-ET-EC-EC-S4-NN-FW?

A: The device peak current specification for this model is 8 A.

Q: What mains voltage range does the HCS01.1E-W0008-A-03-B-ET-EC-EC-S4-NN-FW support?

A: This drive controller is rated for a mains voltage of 3 x AC 200...500 V ±10%.

Q: What is the IP rating for the HCS01.1E-W0008-A-03-B-ET-EC-EC-S4-NN-FW controller?

A: The enclosure has an IP20 rating, indicating limited protection against solid objects and no protection against liquids.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-B-ET-EC-EC-S4-NN-FW is an HCS drive controller that stands out with a BASIC control section and MultiEthernet communication. Internal air cooling through an integrated blower supports stable thermal management, and the 8 A peak current gives this unit solid performance headroom.’’