4.95 based on 202 reviews

🙶 a+ fast delivery 🙷

HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-AA-FW Bosch Rexroth Indramat

MPN: R911331037

No Tariffs On US Orders
  • Rated 4.5 (43 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-AA-FW is part of the HCS IndraDrive Controllers series. This HCS drive controller supports a MultiEthernet communication interface and operates with an input voltage range of 3 x AC 200 to 500 volts. It features an internal air cooling method with an integrated blower and has a peak current of 8 amps.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-AA-FW is a drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. As an HCS drive controller, it regulates torque, speed, and position for servo or induction motors used in automated handling equipment, machining centers, and material transport lines. The unit links motor power stages with higher-level motion sequences, allowing precise closed-loop control during positioning, speed changes, and synchronized axis movement. This role lets one controller manage drive behavior while exchanging command and status data with the rest of the automation system across the machine.

It accepts a three-phase supply of 3 × AC 200–500 V ±10% and can deliver up to 8 A of peak output current to the connected motor stage. Network traffic passes through the integrated MultiEthernet port, giving the controller access to EtherNet/IP, PROFINET, and EtherCAT topologies without extra hardware. The unit is equipped with the BASIC control section, a modular slot that contains the processor and I/O for standard axis functions. Thermal management relies on internal air cooling provided by an embedded blower, which eliminates external ductwork and helps keep the housing within operating limits in compact cabinets. Its compact layout also supports installation in densely packed control panels.

For electrical protection, the housing carries an IP20 rating, so it must be installed inside a closed control panel. Two identical feedback channels support Encoder IndraDyn Hiperface or EnDat 2.1/2.2 signals, allowing redundant position acquisition when high integrity is required. The drive section uses an infeeding/fed power unit, so it can either rectify line energy for the DC bus or share energy recovered from braking with adjacent axes. This model ships with no safety interface, leaving safety tasks to external relays or PLC modules. The power section is matched to its designated control slot within the HCS01 axis module.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0008A03BETECECNNAAFW
  • HCS01 1E W0008 A 03 B ET EC EC NN AA FW
  • hcs01.1e-w0006-a-02-b-et-ec-nn-s5-nn-fw
  • HCS1.1E-W0008-A-03-B-ET-EC-EC-NN-AA-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-AA-FW:

Q: What cooling method is employed in the HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-AA-FW controller?

A: The cooling system on this model uses an internal blower to circulate air for temperature management.

Q: What communication interface is provided with the HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-AA-FW?

A: This device features a MultiEthernet communication interface, supporting multiple Ethernet-based networks.

Q: What is the device peak current of the HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-AA-FW?

A: The peak current supported by this controller is 8 A.

Q: What mains voltage range is required for the HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-AA-FW?

A: This controller operates with a mains voltage range of 3 x AC 200 to 500 V with a tolerance of ±10%.

Q: What IP protection rating does the HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-AA-FW feature?

A: The HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-AA-FW comes with an IP20 rating, indicating limited protection from solid objects but not from liquids.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-AA-FW is an HCS drive controller with MultiEthernet communication and a BASIC control section design. Internal blower cooling and IP20 protection support clean cabinet integration and stable thermal behavior in standard automation panels. The 3 x AC 200 to 500 V mains range makes this controller a strong fit for flexible industrial drive applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo