4.95 based on 202 reviews

🙶 First-time customer with Wake Industrial. The ordering process was completely seamless. The part that we o... 🙷

HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-FW Bosch Rexroth Indramat

MPN: R911339624

No Tariffs On US Orders
  • Rated 4.7 (61 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface and has an 8 Amp peak current. The controller includes STO safe torque off safety, IP20 protection, and uses air cooling through an integrated blower.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-FW is a single-axis drive controller from Bosch Rexroth Indramat in the HCS IndraDrive Controllers series. It belongs to the HCS01 line and combines power electronics with motion control for conveyors, packaging cells, and assembly tools that use low-power servo or induction motors. By placing control, diagnostics, and communication functions in one 65 mm-wide housing, the unit helps conserve cabinet space while still delivering closed-loop torque and speed regulation. It is designed for single-axis applications where accurate current control is needed for repeatable machine motion.

Electrical communication with higher-level PLCs occurs through a MultiEthernet port that supports Profinet, EtherNet/IP, Sercos III, and EtherCAT without add-on cards. The drive uses the BASIC control section, which is suited to standard single-axis motion tasks and routine operating functions. Thermal management relies on internal air cooling driven by an integrated blower, so cabinet air moves across the heat sink to carry away losses during operation. The power stage can deliver up to 8 A peak during dynamic moves, and it operates from 200–500 V AC three-phase mains with a tolerance of ±10%. This lets the same hardware fit automation systems that use different industrial Ethernet standards.

The housing has an IP20 rating, so the controller is intended for installation inside a switchgear cabinet while still providing touch-safe protection after wiring. Functional safety is provided by the dual-channel STO circuit, which removes torque without using mechanical relays. Both feedback ports accept Hiperface/EnDat 2.1/2.2 encoder signals, so either channel can work with the same supported feedback formats. Using the same signal support on both inputs keeps wiring options flexible when matching the drive to compatible motor feedback devices. DC-bus energy is exchanged through an infeeding and fed topology, allowing multiple drives to share one supply module and transfer energy across a common bus.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0008A03BETECECL3NNFW
  • HCS01 1E W0008 A 03 B ET EC EC L3 NN FW
  • hcs01.1e-w0006-a-02-b-et-ec-nn-nn-nn-fw
  • HCS1.1E-W0008-A-03-B-ET-EC-EC-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-FW drive controller?

A: The HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-FW supports MultiEthernet communication for flexible networking.

Q: What is the peak current capacity of the HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-FW?

A: The drive controller operates with a device peak current rating of 8 A.

Q: What cooling method is used in the HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-FW controller?

A: This unit uses an internal air cooling system with an integrated blower.

Q: What is the IP rating of the HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-FW?

A: The HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-FW features an IP20 rating, offering basic protection against solid objects.

Q: What mains voltage is supported by the HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-FW drive controller?

A: The main voltage input range is 3 x AC 200 to 500 V with a ±10% tolerance.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-FW is an HCS drive controller with MultiEthernet communication and an 8 A peak current rating. Internal air cooling through an integrated blower and IP20 protection support dependable cabinet installation in standard industrial environments. STO safety capability makes the BASIC control section a strong choice for precise and secure drive control.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo