The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It has a MultiEthernet communication interface, supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2, and uses internal air cooling with an integrated blower. The device features an IP20 protection rating, operates at a mains voltage range of 3 x AC 200 to 500 V, and has a peak current of 8 Amps.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It belongs to the HCS01 line and serves as the regulated power stage for servo and induction motors in automated production equipment. The unit accepts a three-phase supply, conditions incoming power, and executes motion commands from a PLC. In production systems, it regulates current and voltage so motors can follow commanded speed, torque, and position values. This makes it suitable for packaging, handling, and other automation axes that require repeatable motion.
Communication is handled through MultiEthernet, which supports direct connection to EtherNet/IP, PROFINET, and EtherCAT networks. The mains input range is 3 x AC 200–500 V ±10%, allowing operation on a wide range of industrial power systems. The controller can supply up to 8 A of peak current, and its enclosure is rated IP20, so it is intended for installation inside a control cabinet. Heat is removed by internal air cooling with an integrated blower, which keeps the power section ventilated without requiring an external fan tray. Onboard current monitoring helps protect the output stage during dynamic load changes and short overload events.
Motor feedback is accepted through an Encoder IndraDyn Hiperface/EnDat 2.1/2.2 input, allowing use with compatible high-resolution encoder systems. A second encoder port can be used for redundant or alternate feedback routing, depending on the connected motor arrangement. The DC bus connection follows the Infeeding / Feeded arrangement, which supports common-bus operation with other compatible drives. The unit is design version 1, and the control section is listed as BASIC. This pairing matches the required control section for this unit.
Frequently Asked Questions about HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW:
Q: What type of communication interface is provided on the HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW controller?
A: This drive controller offers MultiEthernet communication for versatile network integration.
Q: What is the peak current handling capability of this HCS IndraDrive Controller model?
A: The HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW supports a peak device current of 8 A.
Q: Which cooling method is utilized by the HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW?
A: The drive controller is cooled internally through an integrated blower for efficient thermal management.
Q: What types of encoder interfaces are available on the HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW?
A: This model features encoder interfaces compatible with IndraDyn Hiperface and EnDat 2.1/2.2 standards.
Q: What is the acceptable mains voltage range for this drive controller?
A: The HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW operates with a 3-phase AC mains voltage ranging from 200 to 500 V ±10%.