The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-B-ET-EC-CN-NN-NN-FW is part of the HCS IndraDrive Controllers series and features a MultiEthernet communication interface and CANopen support. This HCS Drive Controller has a device peak current of 8 Amps, operates at 3 x AC 200 to 500 Volt mains voltage, and uses internal air cooling with an integrated blower. It comes in a BASIC control section design and has an IP20 rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0008-A-03-B-ET-EC-CN-NN-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. In an automation cell, this unit functions as the power and control stage that links a servo motor to the factory mains, converts incoming AC power, and executes drive commands from a higher-level PLC. By combining power electronics with modular control sections, it offers a compact solution for indexing tables, packaging axes, or material-handling gantries that require tightly coordinated motion. The controller is intended for applications where one housing must handle motor power conversion, command processing, and closed-loop axis operation.
The controller accepts a mains supply of 3-phase 200–500 V AC, and its power section can deliver up to 8 A peak current, enabling it to run small to medium IndraDyn motors without external boosters. To prevent dust accumulation and maintain rated output, it uses air cooling with an internal blower, and the housing carries an IP20 rating, so it is intended for installation inside a closed electrical cabinet. Power exchange with the DC bus is managed by an infeeding and regenerative power section, allowing the module to draw or return energy depending on the load cycle. Real-time network traffic, fault monitoring, and parameter storage are handled by the plug-in control section.
For command and feedback channels, the unit offers MultiEthernet for system-wide motion coordination and a separate CANopen bus for service diagnostics or decentralized I/O. Motor feedback arrives over the IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, which supports commutation and position evaluation with compatible motors. This layout allows motion control and service communication to remain on separate channels during operation. Axis safety is handled externally because no safety interface is installed at the factory. The control section is a Basic control section matched to the HCS01 line, and it carries Design Version 1 electronics.
Frequently Asked Questions about HCS01.1E-W0008-A-03-B-ET-EC-CN-NN-NN-FW:
Q: What communication interface does the HCS01.1E-W0008-A-03-B-ET-EC-CN-NN-NN-FW use?
A: The HCS01.1E-W0008-A-03-B-ET-EC-CN-NN-NN-FW supports MultiEthernet as its main communication interface for flexible industrial networking.
Q: How is the HCS01.1E-W0008-A-03-B-ET-EC-CN-NN-NN-FW cooled?
A: This model uses internal air cooling through an integrated blower for temperature management.
Q: What is the device peak current of the HCS01.1E-W0008-A-03-B-ET-EC-CN-NN-NN-FW?
A: The peak current supported by this drive controller is 8 A.
Q: What mains voltage range does the HCS01.1E-W0008-A-03-B-ET-EC-CN-NN-NN-FW support?
A: This device is designed to operate with a mains voltage range of 3 x AC 200 to 500 V ±10%.
Q: What IP rating is assigned to the HCS01.1E-W0008-A-03-B-ET-EC-CN-NN-NN-FW drive controller?
A: The HCS01.1E-W0008-A-03-B-ET-EC-CN-NN-NN-FW has an IP20 rating, offering basic protection against solid objects.