4.95 based on 202 reviews

🙶 Easy to navigate website and quick responses from support. Additionally, pretty fast shipping. Our mainte... 🙷

HCS01.1E-W0008-A-03-A-ET-EC-NN-S5-NN-FW Bosch Rexroth Indramat

MPN: R911398655

Ask for Availability
Current Response Time 6 min 15 sec

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-A-ET-EC-NN-S5-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller supports a MultiEthernet communication interface and has a peak current rating of 8 Amps. It uses an internal air cooling method with an integrated blower and is built with an IP20 protection rating.

No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The HCS01.1E-W0008-A-03-A-ET-EC-NN-S5-NN-FW is an HCS drive controller with MultiEthernet communication and IP20 protection. Internal blower cooling and 8 A peak current deliver efficient thermal control and dependable dynamic response. A strong choice for cabinet-based motion applications.

Sell Part Have a part to sell?
Warranty Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-A-ET-EC-NN-S5-NN-FW is a drive controller produced by Bosch Rexroth Indramat and part of the HCS IndraDrive Controllers series. In an automation cell, it forms the power and control interface between the plant’s AC mains and a connected motor, processing command data and encoder feedback so the axis follows velocity, torque, or position profiles from a higher-level PLC. Communication is handled through an integrated MultiEthernet port, which carries motion commands and status updates over several industrial Ethernet protocols. This arrangement lets the controller fit machines that need networked motion control without adding a separate communication module or gateway.

The power stage accepts a three-phase supply of 3 × AC 200–500 V ±10%, covering common low- and medium-voltage networks without a transformer. During rapid acceleration, current drawn from the DC link can reach 8 A, so upstream protection and conductor sizing must account for that demand. The enclosure has an IP20 rating, which means the controller is intended for installation inside a closed cabinet rather than in open machine areas. Motor position data enters through the first feedback connection, which supports IndraDyn Hiperface and EnDat 2.1/2.2 encoders for closed-loop control. This feedback path gives the drive the position information it needs for commutation, speed regulation, and accurate axis response during motion.

Thermal management relies on internal air cooling generated by an integrated blower, which keeps the housing compact and avoids the need for external heat sinks. Power is exchanged over a DC bus that supports infeeding and feeding operation, allowing braking energy from one axis to be used elsewhere in a multi-axis system. The controller uses a BASIC control section for standard motion tasks, including routine speed, torque, and position control. The unit is Design Version 1, and the second encoder port is not populated. With only the primary feedback channel installed, the layout stays focused on single-feedback applications.

Communication Interface
MultiEthernet
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller

Frequently Asked Questions about HCS01.1E-W0008-A-03-A-ET-EC-NN-S5-NN-FW:

Q: What kind of communication interface is available on the HCS01.1E-W0008-A-03-A-ET-EC-NN-S5-NN-FW?

A: The HCS01.1E-W0008-A-03-A-ET-EC-NN-S5-NN-FW supports MultiEthernet communication for network integration.

Q: What cooling method does the HCS01.1E-W0008-A-03-A-ET-EC-NN-S5-NN-FW use?

A: This drive controller features integrated internal air cooling through a built-in blower system for heat dissipation.

Q: What is the peak current rating for the HCS01.1E-W0008-A-03-A-ET-EC-NN-S5-NN-FW?

A: The maximum device peak current for this unit is 8 A.

Q: Which encoder interfaces are provided on the HCS01.1E-W0008-A-03-A-ET-EC-NN-S5-NN-FW?

A: Encoder IndraDyn Hiperface/EnDat 2.1/2.2 is supported as Interface 1 on this controller.

Q: What mains voltage is required to operate the HCS01.1E-W0008-A-03-A-ET-EC-NN-S5-NN-FW drive controller?

A: The HCS01.1E-W0008-A-03-A-ET-EC-NN-S5-NN-FW operates with a 3-phase AC supply voltage of 200 to 500 V ±10%.

  • HCS011EW0008A03AETECNNS5NNFW
  • HCS01 1E W0008 A 03 A ET EC NN S5 NN FW
  • hcs01.1e-w0006-a-02-b-et-ec-ep-nn-nn-fw
  • HCS1.1E-W0008-A-03-A-ET-EC-NN-S5-NN-FW
Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo