4.95 based on 202 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

HCS01.1E-W0008-A-03-A-ET-EC-NN-L3-NN-FW Bosch Rexroth Indramat

MPN: R911383799

No Tariffs On US Orders
  • Rated 4.5 (38 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Available, Ships in 1-2 weeks

Current response time:
4 Minutes 49 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-A-ET-EC-NN-L3-NN-FW is part of the HCS IndraDrive Controllers series and is classified as an HCS drive controller. It features MultiEthernet communication, supports a main voltage range of 3 x AC 200 to 500 V, and delivers a device peak current of 8 Amps. Air cooling is accomplished through an integrated blower, and the unit has an IP20 rating along with an STO safety interface.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-A-ET-EC-NN-L3-NN-FW drive controller is manufactured by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. Belonging to the HCS01 line and delivered in design version 1, the device forms the power stage that links a multi-voltage industrial power supply to servo or induction motors used in automated machinery. Its role is to convert incoming three-phase energy into a controlled pulse-width-modulated output so that individual motion axes receive precise torque and speed profiles during production cycles.

The controller accepts a three-phase supply of 3 × AC 200…500 V ±10 %, allowing installation on low- or medium-voltage distribution networks. During rapid acceleration, the power stage can deliver a peak output of 8 A, a current capacity suited to small feeders, pick-and-place arms, or auxiliary conveyors. Thermal energy is removed by internal air cooling through an integrated blower, so no external heat sink or cabinet fan is required. Networked control is achieved through the onboard MultiEthernet interface, which supports several real-time fieldbuses without additional option cards. Protection against finger contact and settled dust is provided by the IP20 enclosure rating, so cabinet installation is required while internal wiring remains accessible.

For feedback, the power section offers an IndraDyn Hiperface/EnDat 2.1/2.2 encoder input, ensuring that high-resolution absolute position data reaches the drive. A second feedback channel is not equipped, which reduces hardware complexity. Functional safety is provided by the integrated STO (Safe Torque Off) circuit, which removes drive energy without mechanical relays. DC-link energy is exchanged through an infeeding and feeding power supply design, enabling operation on a common bus with regenerative axes. Application software is not embedded at delivery, so firmware must be ordered separately. The unit is used with BASIC control sections.

Communication Interface
MultiEthernet
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0008A03AETECNNL3NNFW
  • HCS01 1E W0008 A 03 A ET EC NN L3 NN FW
  • hcs01.1e-w0006-a-02-b-et-ec-em-s4-nn-fw
  • HCS1.1E-W0008-A-03-A-ET-EC-NN-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-A-ET-EC-NN-L3-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0008-A-03-A-ET-EC-NN-L3-NN-FW controller?

A: The HCS01.1E-W0008-A-03-A-ET-EC-NN-L3-NN-FW supports communication via MultiEthernet interface.

Q: How is the HCS01.1E-W0008-A-03-A-ET-EC-NN-L3-NN-FW cooled during operation?

A: This device uses internal air cooling provided by an integrated blower.

Q: What is the device peak current for the HCS01.1E-W0008-A-03-A-ET-EC-NN-L3-NN-FW?

A: The peak current supported by this drive controller is 8 A.

Q: What is the mains voltage range for the HCS01.1E-W0008-A-03-A-ET-EC-NN-L3-NN-FW?

A: The HCS01.1E-W0008-A-03-A-ET-EC-NN-L3-NN-FW operates with a mains voltage of 3 x AC 200...500 V ±10%.

Q: What type of safety interface does the HCS01.1E-W0008-A-03-A-ET-EC-NN-L3-NN-FW provide?

A: This model features an STO (Safe Torque Off) safety interface for enhanced operational safety.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-A-ET-EC-NN-L3-NN-FW is an HCS drive controller with MultiEthernet communication and an IP20 enclosure. Internal blower cooling and a 3 x AC 200...500 V ±10% mains range support stable cabinet integration across varied machine platforms. STO Safe Torque Off and an 8 A peak current give the controller a well-balanced combination of protection and drive capability.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo