4.95 based on 202 reviews

🙶 First-time customer with Wake Industrial. The ordering process was completely seamless. The part that we o... 🙷

HCS01.1E-W0008-A-03-A-ET-EC-EM-L3-NN-FW Bosch Rexroth Indramat

MPN: R911401000

No Tariffs On US Orders
  • Rated 4.5 (68 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-A-ET-EC-EM-L3-NN-FW is part of the HCS IndraDrive Controllers series and features a MultiEthernet communication interface. This HCS Drive Controller provides a device peak current of 8 Amps, uses air cooling through an integrated blower, and has an IP20 rating. It supports encoder interfaces including IndraDyn Hiperface and EnDat 2.1/2.2, and is equipped with an STO safety interface.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-A-ET-EC-EM-L3-NN-FW is a drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. As part of the HCS01 line, this unit serves as the power-stage link between the mains supply and servo axes in automated machinery, providing regulated power conversion and motion commands for industrial automation tasks. It is intended for servo axes in packaging, handling, and general automation equipment where compact drive modules are mounted inside a control cabinet. Its role is to convert incoming electrical power into controlled motor output while coordinating motion responses with the higher-level control system.

The controller accepts a three-phase input of 3 × AC 200 to 500 V ±10 %, allowing operation on a wide range of industrial power systems. It can supply a device peak current of 8 A, which supports short periods of higher motor demand during acceleration or load changes. Thermal management relies on internal air cooling from an integrated blower, and the housing has an IP20 rating for installation inside protected cabinets. Communication is handled through a MultiEthernet port, allowing real-time network exchange with compatible automation platforms.

Functional safety is provided by STO, which disables torque-producing energy without switching off the main supply. Position feedback at Interface 1 supports Encoder IndraDyn Hiperface/EnDat 2.1/2.2, while Interface 2 can provide encoder emulation for systems that need a conventional feedback signal. That combination allows the drive to work with modern servo motors while still providing a usable signal to connected legacy controls. The unit is Design Version 1 and uses a BASIC control section with an infeeding/feeded power supply scheme. The power stage supports both motoring and regenerative operation, allowing returned energy from decelerating axes to be handled within the drive system.

Communication Interface
MultiEthernet
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0008A03AETECEML3NNFW
  • HCS01 1E W0008 A 03 A ET EC EM L3 NN FW
  • hcs01.1e-w0006-a-02-b-et-ec-ec-s5-nn-aw
  • HCS1.1E-W0008-A-03-A-ET-EC-EM-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-A-ET-EC-EM-L3-NN-FW:

Q: What type of communication interface is available on the HCS01.1E-W0008-A-03-A-ET-EC-EM-L3-NN-FW controller?

A: The HCS01.1E-W0008-A-03-A-ET-EC-EM-L3-NN-FW supports MultiEthernet communication for versatile network connectivity.

Q: How is the HCS01.1E-W0008-A-03-A-ET-EC-EM-L3-NN-FW cooled during operation?

A: Cooling is achieved internally through an integrated blower in this drive controller.

Q: What is the device peak current capability of the HCS01.1E-W0008-A-03-A-ET-EC-EM-L3-NN-FW?

A: This model features a device peak current rating of 8 A.

Q: Which encoder interfaces are available on the HCS01.1E-W0008-A-03-A-ET-EC-EM-L3-NN-FW controller?

A: Both IndraDyn Hiperface and EnDat 2.1/2.2 encoder connections are supported via Interface 1.

Q: What type of environmental protection does the HCS01.1E-W0008-A-03-A-ET-EC-EM-L3-NN-FW provide?

A: The IP rating of this controller is IP20, offering basic protection against solid objects.