4.95 based on 202 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

HCS01.1E-W0008-A-03-A-ET-EC-EC-NN-NN-FW Bosch Rexroth Indramat

MPN: R911377463

No Tariffs On US Orders
  • Rated 4.6 (61 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-A-ET-EC-EC-NN-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It supports a peak current of 8 Amps and operates on a mains voltage of 3 x AC 200 to 500 Volts. The controller features MultiEthernet communication interfaces and uses internal air cooling with an integrated blower.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-A-ET-EC-EC-NN-NN-FW is an HCS drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It belongs to the compact HCS01 line and serves as the power stage for regulating current and voltage to servo or induction motors in automated equipment. When combined with an external BASIC control section, the unit supports closed-loop torque and speed control in assembly stations, packaging machines, and conveyor systems. Its narrow housing helps conserve cabinet space in installations where a small footprint is important.

The drive has a rated device peak current of 8 A, which allows it to handle short-term load demand within its intended operating range. It accepts a mains connection of 3 x AC 200…500 V ±10%, which supports use across a broad range of industrial power systems. Heat is removed by internal air cooling through an integrated blower, so no external ducting is required. For network communication, the unit uses a MultiEthernet interface that can support several industrial Ethernet protocols. Cabinet installation is required because the enclosure has an IP20 rating, which protects against accidental contact with internal parts but is not intended for exposed mounting.

The product is built as version 1 of this design. Two feedback ports accept encoder signals that follow the IndraDyn Hiperface/EnDat 2.1/2.2 standard, allowing position information to reach the control section without additional converter hardware. Its DC-link arrangement is listed as infeeding and feeded, meaning it can supply energy to a shared bus or draw energy from it, depending on the system layout. The safety interface is not equipped, so any required risk-reduction functions must be provided by external circuitry. This layout keeps the controller focused on motor power conversion, communication, and feedback handling within the cabinet-based drive system.

Communication Interface
MultiEthernet
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0008A03AETECECNNNNFW
  • HCS01 1E W0008 A 03 A ET EC EC NN NN FW
  • hcs01.1e-w0006-a-02-b-et-ec-ec-nn-nn-fw
  • HCS1.1E-W0008-A-03-A-ET-EC-EC-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-A-ET-EC-EC-NN-NN-FW:

Q: What is the peak current capability of the HCS01.1E-W0008-A-03-A-ET-EC-EC-NN-NN-FW drive controller?

A: The HCS01.1E-W0008-A-03-A-ET-EC-EC-NN-NN-FW operates with a device peak current of 8 A for handling demanding drive applications.

Q: What type of communication interface is available on the HCS01.1E-W0008-A-03-A-ET-EC-EC-NN-NN-FW?

A: This model is equipped with a MultiEthernet communication interface, providing flexible networking options for integration.

Q: How is the HCS01.1E-W0008-A-03-A-ET-EC-EC-NN-NN-FW cooled during operation?

A: The HCS01.1E-W0008-A-03-A-ET-EC-EC-NN-NN-FW uses air cooling with an internal integrated blower for thermal management.

Q: What mains voltage range does the HCS01.1E-W0008-A-03-A-ET-EC-EC-NN-NN-FW support?

A: This drive controller supports a mains voltage range of 3 x AC 200...500 V with a tolerance of ±10%.

Q: What encoder interface types are available on the HCS01.1E-W0008-A-03-A-ET-EC-EC-NN-NN-FW?

A: The HCS01.1E-W0008-A-03-A-ET-EC-EC-NN-NN-FW features encoder interfaces compatible with IndraDyn Hiperface and EnDat 2.1/2.2 standards.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-A-ET-EC-EC-NN-NN-FW is an HCS drive controller that stands out for efficient machine integration with MultiEthernet communication. Internal air cooling through an integrated blower and 3 x AC 200...500 V ±10% mains support give the unit solid thermal control and application flexibility. An 8 A peak current rating with IP20 protection makes the controller a strong choice for enclosed industrial drive systems.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo