HCS01.1E-W0008-A-03-A-ET-EC-EC-L3-NN-FW Bosch Rexroth Indramat
MPN: R911382240
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-A-ET-EC-EC-L3-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface and operates at a device peak current of 8 Amps with a mains voltage range of 3 x AC 200 to 500 Volts. Internal air cooling is achieved through an integrated blower, and the controller offers IP20 protection and STO safety interface.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0008-A-03-A-ET-EC-EC-L3-NN-FW belongs to the HCS IndraDrive Controllers series manufactured by Bosch Rexroth Indramat. As a drive controller, it forms the power and regulation stage between a plant PLC and a servo or induction motor. It converts control commands into regulated electrical output so the connected axis can follow velocity and torque demands during automated motion. That role lets the controller regulate motor behavior directly rather than leaving current control to higher-level automation hardware. The unit is part of the HCS01 family and is suited for assembly cells, material-handling stations, and similar industrial equipment.
The controller exchanges data with supervisory equipment through a MultiEthernet port that supports common real-time Ethernet protocols. Internal heat is removed by internal air cooling through an integrated blower, so no external ducting is needed inside the cabinet. This cooling method keeps the enclosure layout simple and avoids separate external air channels for the drive itself. For short accelerations, it can deliver a peak output of 8 A, which supports temporary higher demand during dynamic motion. The input section accepts 3 × AC 200…500 V ±10%, allowing operation from a wide range of three-phase mains supplies. Its IP20 housing is intended for installation in a protected enclosure, where airflow and protection from accidental contact can be managed at the cabinet level.
Functional safety is provided through STO (Safe Torque Off), which removes torque-producing power for stop functions without requiring separate power contactors in the drive path. The DC link uses infeeding / bus-fed operation, allowing the unit to work within a shared bus arrangement that can return or consume energy according to the power-supply layout. Position feedback is handled by a dual encoder input for IndraDyn Hiperface and EnDat 2.1/2.2, supporting motor feedback together with external encoder monitoring. Shared power structures and closed-loop feedback can be used in coordinated multi-axis installations.
Frequently Asked Questions about HCS01.1E-W0008-A-03-A-ET-EC-EC-L3-NN-FW:
Q: What type of communication interface does the HCS01.1E-W0008-A-03-A-ET-EC-EC-L3-NN-FW support?
A: The HCS01.1E-W0008-A-03-A-ET-EC-EC-L3-NN-FW supports MultiEthernet communication for flexible network connectivity.
Q: How is the HCS01.1E-W0008-A-03-A-ET-EC-EC-L3-NN-FW cooled?
A: This drive controller uses internal air cooling through an integrated blower.
Q: What is the peak current supported by the HCS01.1E-W0008-A-03-A-ET-EC-EC-L3-NN-FW?
A: The device has a peak current rating of 8 A.
Q: What input mains voltage range does the HCS01.1E-W0008-A-03-A-ET-EC-EC-L3-NN-FW require?
A: The HCS01.1E-W0008-A-03-A-ET-EC-EC-L3-NN-FW accepts a mains voltage of 3 x AC 200 to 500 V ±10%.
Q: What safety interface is offered with the HCS01.1E-W0008-A-03-A-ET-EC-EC-L3-NN-FW?
A: This model features the Safe Torque Off (STO) safety interface.