4.95 based on 202 reviews

🙶 a+ fast delivery 🙷

HCS01.1E-W0008-A-03-A-CC-EC-PB-S4-NN-FW Bosch Rexroth Indramat

MPN: R911345012

No Tariffs On US Orders
  • Rated 4.3 (54 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships Fast

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-A-CC-EC-PB-S4-NN-FW is a drive controller in the HCS IndraDrive Controllers series. It features a SERCOS III master communication interface and includes both PROFIBUS and encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2. The controller has a device peak current of 8 Amps, an internal air cooling system with integrated blower, and an IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-A-CC-EC-PB-S4-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It serves as the power and control stage between the mains supply and IndraDyn servo motors, enabling position, velocity, and torque regulation in automated machinery. This layout lets the controller convert incoming electrical power into regulated motor output while maintaining closed-loop response during changing loads. It is suited for applications that require coordinated axis control and stable servo performance.

It accepts a three-phase mains voltage of 3 x AC 200–500 V ±10%, allowing deployment on standard plant distribution networks. For short duty cycles, it can deliver up to 8 A of peak current, matching the requirements of low-power IndraDyn axes. Thermal management relies on internal air cooling driven by the integrated blower, so no supplementary ducting is required inside the cabinet. The enclosure has an IP20 rating, which provides touch-safe terminals but no protection against liquids. Communication between multiple drives is handled by the SERCOS III master channel, which supports cross-communication for synchronized motion. The unit can operate in an infeeding or fed power-supply role, simplifying energy sharing on a multi-axis DC bus. This arrangement supports compact cabinet installations where airflow and power distribution must remain straightforward.

The control section mounted on this base drive is classified as ADVANCED, and the installed design is version 1. Encoder feedback enters through Interface 1, which supports Hiperface/EnDat 2.1/2.2 protocols for absolute position data from IndraDyn motors. Fieldbus coupling to higher-level PLCs is offered through the dedicated PROFIBUS port. Within the HCS01 line, the controller shares mechanical dimensions that allow side-by-side mounting, and its infeeding or fed topology supports common DC bus links on multi-axis racks. This combination lets the drive exchange motion data with the control system while receiving absolute motor feedback through the matching encoder interface.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
PROFIBUS
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0008A03ACCECPBS4NNFW
  • HCS01 1E W0008 A 03 A CC EC PB S4 NN FW
  • hcs01.1e-w0006-a-02-b-et-ec-ec-l4-nn-aw
  • HCS1.1E-W0008-A-03-A-CC-EC-PB-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-A-CC-EC-PB-S4-NN-FW:

Q: What cooling method is used in the HCS01.1E-W0008-A-03-A-CC-EC-PB-S4-NN-FW drive controller?

A: This drive controller features an internal air cooling system using an integrated blower for heat management.

Q: What is the device peak current rating of the HCS01.1E-W0008-A-03-A-CC-EC-PB-S4-NN-FW?

A: The drive controller operates with a peak current of 8 A, supporting drives that require this current limit.

Q: What is the primary communication interface on the HCS01.1E-W0008-A-03-A-CC-EC-PB-S4-NN-FW?

A: This controller includes a SERCOS III master communication interface with cross communication capability.

Q: Which encoder interfaces are available on this drive controller?

A: The HCS01.1E-W0008-A-03-A-CC-EC-PB-S4-NN-FW supports encoder interfaces including IndraDyn Hiperface and EnDat 2.1/2.2.

Q: What is the IP rating of the HCS01.1E-W0008-A-03-A-CC-EC-PB-S4-NN-FW drive controller?

A: This model has an IP20 rating, providing basic protection against solid objects but no protection from water.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-A-CC-EC-PB-S4-NN-FW is an HCS drive controller with an ADVANCED control section and internal air cooling through an integrated blower. SERCOS III master cross communication and a PROFIBUS interface support flexible network integration in multi-axis systems. An 8 A peak current and 3 x AC 200...500 V mains input make this controller a strong fit for compact industrial drive architectures.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo