HCS01.1E-W0008-A-03-A-CC-EC-PB-NN-NN-FW Bosch Rexroth Indramat
MPN: R911339333
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-A-CC-EC-PB-NN-NN-FW is part of the HCS IndraDrive Controllers series. This HCS drive controller features SERCOS III and PROFIBUS communication interfaces and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2. It offers 8 A device peak current, operates at 3 x AC 200 to 500 V, and uses an internal air cooling system with an IP20 rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0008-A-03-A-CC-EC-PB-NN-NN-FW is a drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. In multi-axis automation, it converts incoming three-phase power and coordinates motion commands between control sections and intelligent drives. The unit operates as an axis inverter within a modular IndraDrive system, allowing servo and asynchronous motors to be regulated from a central motion platform. That arrangement supports both precise positioning tasks and speed-controlled motor applications in compact machine layouts. Because it is part of a modular platform, power conversion and motion control remain centralized while each axis retains dedicated inverter hardware.
This controller accepts a mains supply of 3 x AC 200…500 V ±10%, allowing connection to common industrial power systems. A device peak current of 8 A supports short-term output during acceleration or braking events. Network traffic is exchanged through a SERCOS III master channel that supports cross-communication between drives, while a secondary bus based on PROFIBUS permits connection to conventional PLC architectures. Motor feedback is processed through the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface, supporting absolute position data at power-up. The housing has an IP20 rating, so the unit must be installed inside a protected cabinet. Heat is removed by internal air cooling, which uses an integrated blower to control semiconductor temperature.
The installed control section is labeled ADVANCED, and it adds embedded logic functions for more complex axis coordination within the drive system. The unit uses an infeeding/fed power supply concept, so regenerative energy on the DC bus can be shared with connected modules or returned through the system supply path. The product is design version 1, and no integrated safety interface is included. Software must be selected separately so the drive can be matched to the motor and application.
Frequently Asked Questions about HCS01.1E-W0008-A-03-A-CC-EC-PB-NN-NN-FW:
Q: What communication interface does the HCS01.1E-W0008-A-03-A-CC-EC-PB-NN-NN-FW controller use?
A: The HCS01.1E-W0008-A-03-A-CC-EC-PB-NN-NN-FW features a SERCOS III master interface for cross communication.
Q: What is the control section design type of the HCS01.1E-W0008-A-03-A-CC-EC-PB-NN-NN-FW?
A: This controller is equipped with an ADVANCED control section design type.
Q: How is the HCS01.1E-W0008-A-03-A-CC-EC-PB-NN-NN-FW controller cooled?
A: The cooling method for this unit is air, using an integrated internal blower to maintain optimal temperature.
Q: What mains voltage range does the HCS01.1E-W0008-A-03-A-CC-EC-PB-NN-NN-FW support?
A: This model operates on mains voltages ranging from 3 x AC 200 to 500 V ±10%.
Q: What is the peak current rating of the HCS01.1E-W0008-A-03-A-CC-EC-PB-NN-NN-FW controller?
A: The device has a peak current rating of 8 A.