4.95 based on 202 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

HCS01.1E-W0008-A-03-A-CC-EC-PB-L3-NN-FW Bosch Rexroth Indramat

MPN: R911338262

No Tariffs On US Orders
  • Rated 4.5 (50 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-A-CC-EC-PB-L3-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a device peak current of 8 Amps and an IP20 rating with an internal air cooling method using an integrated blower. This unit includes SERCOS III master and PROFIBUS communication interfaces, and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-A-CC-EC-PB-L3-NN-FW belongs to the HCS IndraDrive Controllers series from Bosch Rexroth Indramat. It is a compact drive controller used to regulate servo or induction axes in modular machine platforms, providing closed-loop speed and torque control while coordinating with upper-level PLCs. This makes it suitable for positioning tasks, variable-speed operation, and synchronized axis control in automated equipment. The unit is part of line HCS01 and design version 1 within the HCS controller platform.

This controller draws its three-phase supply from 3 x AC 200...500 V ±10%, allowing operation on a broad range of plant mains services. During acceleration events, the inverter stage can deliver up to 8 A of peak current to the connected motor. The housing is rated IP20, so the unit must be installed inside an electrical cabinet to protect it from contact and contamination. Thermal management relies on internal air cooling through an integrated blower, which removes heat without external ducting. An integrated safety input implements STO (Safe Torque Off), removing motor torque when the safety circuit is triggered. The power section uses an infeeding/feeded arrangement, so it can return braking energy to a shared DC bus or accept power from it.

Field communication is handled through a SERCOS III master (cross communication) port that supports synchronized motion between multiple drives on the network. Legacy automation systems can also connect through PROFIBUS on the same control section, which adds flexibility when the drive is used in mixed communication environments. Motor feedback is accepted through the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface, allowing compatibility with supported encoder types and direct position feedback. The controller is paired with the ADVANCED control section, placing motion control, communication handling, and feedback processing in one compact assembly.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
PROFIBUS
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0008A03ACCECPBL3NNFW
  • HCS01 1E W0008 A 03 A CC EC PB L3 NN FW
  • hcs01.1e-w0006-a-02-b-et-ec-da-nn-nn-fw
  • HCS1.1E-W0008-A-03-A-CC-EC-PB-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-A-CC-EC-PB-L3-NN-FW:

Q: What communication interface does the HCS01.1E-W0008-A-03-A-CC-EC-PB-L3-NN-FW controller use?

A: The HCS01.1E-W0008-A-03-A-CC-EC-PB-L3-NN-FW controller is equipped with a SERCOS III master communication interface for cross communication.

Q: How is the HCS01.1E-W0008-A-03-A-CC-EC-PB-L3-NN-FW cooled?

A: This drive controller uses an internal air cooling system with an integrated blower for thermal management.

Q: What type of safety interface is available on the HCS01.1E-W0008-A-03-A-CC-EC-PB-L3-NN-FW controller?

A: The safety interface on this model features STO (Safe Torque Off) functionality for secure operation.

Q: What is the device peak current for the HCS01.1E-W0008-A-03-A-CC-EC-PB-L3-NN-FW?

A: The device can handle a peak current of 8 A during operation.

Q: What is the supported mains voltage range for the HCS01.1E-W0008-A-03-A-CC-EC-PB-L3-NN-FW controller?

A: This controller supports mains voltages from 3 x AC 200 to 500 V with a tolerance of plus or minus 10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-A-CC-EC-PB-L3-NN-FW is an HCS drive controller with an ADVANCED control section. Internal air cooling and a 3 x AC 200...500 V ±10% mains range support stable operation across a wide set of industrial drive applications. SERCOS III master cross communication adds strong system integration value and stands out as a key capability.’’