4.95 based on 202 reviews

🙶 a+ fast delivery 🙷

HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW Bosch Rexroth Indramat

MPN: R911386156

No Tariffs On US Orders
  • Rated 4.6 (54 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller features SERCOS III master cross communication and a device peak current of 8 Amps. It uses internal air cooling with an integrated blower and is rated IP20 for protection.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW is a single-axis drive controller from Bosch Rexroth Indramat in the HCS IndraDrive Controllers series. It is installed in industrial machines to convert three-phase mains power into regulated DC-bus energy and to execute position, velocity, and torque loops for a connected motor. By integrating power electronics and motion logic in one module, the unit simplifies cabinet wiring and supports coordinated axes within packaging, printing, and handling equipment. This arrangement helps the drive fit compact control cabinets where a separate motion controller is not required for routine axis tasks.

The controller exchanges cyclic setpoints and status words over a SERCOS III master with cross communication interface, permitting deterministic 1 ms update periods across multiple axes. Internal application functions run on the ADVANCED control section, which supports interpolation, safety gating, and logic sequencing without an external PC. Thermal management relies on internal air cooling through an integrated blower, so the fan draws cabinet air through the heat sinks without requiring ducted exhaust. The power stage supplies up to 8 A of peak current and is rated for 3 x AC 200 to 500 V ±10%. Hardware is classified as design version 1, and this frame uses the A-type control card with matching connectors and memory capacity.

The feedback port accepts IndraDyn Hiperface and EnDat 2.1/2.2 encoder feedback, enabling single-turn and multi-turn absolute measurement without separate batteries. A second encoder interface is not included, so unused I/O channels are omitted. The housing meets IP20 protection, so live parts must remain inside a grounded enclosure. Power sharing follows an infeed/feed operating principle, allowing regenerated energy to move onto the common DC bus or back to the mains. This arrangement suits systems that share braking energy across interconnected axes during dynamic deceleration. Axis functions require a separately ordered software option selected during project planning.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0008A03ACCECNNS5NNFW
  • HCS01 1E W0008 A 03 A CC EC NN S5 NN FW
  • hcs01.1e-w0006-a-02-b-et-ec-cn-nn-nn-fw
  • HCS1.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW:

Q: What cooling method does the HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW drive controller utilize?

A: The HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW is equipped with an internal air cooling system using an integrated blower.

Q: What communication interface is provided on the HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW?

A: This model supports SERCOS III master communication with cross communication capabilities.

Q: What is the peak current rating of the HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW drive?

A: The peak current supported by this device is 8 A during operation.

Q: Which encoder interfaces are compatible with the HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW?

A: The primary encoder interface types available are IndraDyn Hiperface and EnDat 2.1/2.2.

Q: What is the IP rating of the HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW drive controller?

A: This drive controller has an IP20 rating, indicating limited protection against dust and no protection against water.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW is an HCS drive controller with an ADVANCED control section and SERCOS III master cross communication. Internal air cooling through an integrated blower supports stable thermal performance, and 8 A peak current suits responsive motion applications. IP20 protection rounds out a capable controller for well-managed industrial enclosures.’’