HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW Bosch Rexroth Indramat
MPN: R911386156
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller features SERCOS III master cross communication and a device peak current of 8 Amps. It uses internal air cooling with an integrated blower and is rated IP20 for protection.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW is a single-axis drive controller from Bosch Rexroth Indramat in the HCS IndraDrive Controllers series. It is installed in industrial machines to convert three-phase mains power into regulated DC-bus energy and to execute position, velocity, and torque loops for a connected motor. By integrating power electronics and motion logic in one module, the unit simplifies cabinet wiring and supports coordinated axes within packaging, printing, and handling equipment. This arrangement helps the drive fit compact control cabinets where a separate motion controller is not required for routine axis tasks.
The controller exchanges cyclic setpoints and status words over a SERCOS III master with cross communication interface, permitting deterministic 1 ms update periods across multiple axes. Internal application functions run on the ADVANCED control section, which supports interpolation, safety gating, and logic sequencing without an external PC. Thermal management relies on internal air cooling through an integrated blower, so the fan draws cabinet air through the heat sinks without requiring ducted exhaust. The power stage supplies up to 8 A of peak current and is rated for 3 x AC 200 to 500 V ±10%. Hardware is classified as design version 1, and this frame uses the A-type control card with matching connectors and memory capacity.
The feedback port accepts IndraDyn Hiperface and EnDat 2.1/2.2 encoder feedback, enabling single-turn and multi-turn absolute measurement without separate batteries. A second encoder interface is not included, so unused I/O channels are omitted. The housing meets IP20 protection, so live parts must remain inside a grounded enclosure. Power sharing follows an infeed/feed operating principle, allowing regenerated energy to move onto the common DC bus or back to the mains. This arrangement suits systems that share braking energy across interconnected axes during dynamic deceleration. Axis functions require a separately ordered software option selected during project planning.
Frequently Asked Questions about HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW:
Q: What cooling method does the HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW drive controller utilize?
A: The HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW is equipped with an internal air cooling system using an integrated blower.
Q: What communication interface is provided on the HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW?
A: This model supports SERCOS III master communication with cross communication capabilities.
Q: What is the peak current rating of the HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW drive?
A: The peak current supported by this device is 8 A during operation.
Q: Which encoder interfaces are compatible with the HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW?
A: The primary encoder interface types available are IndraDyn Hiperface and EnDat 2.1/2.2.
Q: What is the IP rating of the HCS01.1E-W0008-A-03-A-CC-EC-NN-S5-NN-FW drive controller?
A: This drive controller has an IP20 rating, indicating limited protection against dust and no protection against water.