HCS01.1E-W0008-A-03-A-CC-EC-ET-SB-NN-FW Bosch Rexroth Indramat
MPN: R911387373
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
5 Minutes
47 Seconds
The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-A-CC-EC-ET-SB-NN-FW is part of the HCS IndraDrive Controllers series and features an internal air cooling method with an integrated blower. This drive controller has a device peak current of 8 Amps, supports SERCOS III master cross communication, and includes MultiEthernet and specialized encoder interfaces.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Bosch Rexroth Indramat manufactures the HCS01.1E-W0008-A-03-A-CC-EC-ET-SB-NN-FW drive controller as part of the HCS IndraDrive Controllers series. Within the HCS01 line, this unit functions as a compact power stage that converts mains energy into regulated motor current for servo or induction axes used in automated machinery. It includes a detachable control section that closes the motion loop and coordinates multi-axis tasks, enabling precise torque, speed, and position control where cabinet space, thermal management, and deterministic networking are critical. This arrangement allows the power section and control electronics to work together for coordinated axis operation in automated systems.
The power module accepts 3 × AC 200…500 V ±10% and can supply up to 8 A of peak current to the connected motor. Energy exchange with the DC bus uses infeeding and regenerative operation, which supports shared bus operation and returned energy flow during deceleration. Heat is removed by internal air cooling with an integrated blower, so no external ducts are required. This cooling method helps keep the housing compact while moving heat away from the power electronics. The enclosure has an IP20 rating and therefore must be installed inside a closed control cabinet. The unit is design version 1 and uses the standard physical layout for this controller type.
The logic layer uses the ADVANCED control section. Real-time motion commands travel over a SERCOS III master link that also supports cross-communication between drives. Feedback is handled through the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 port, while supervisory controllers can access diagnostics and parameter sets through the MultiEthernet service interface that supports EtherNet/IP, PROFINET, and EtherCAT. Using separate motion and service interfaces allows deterministic axis control to remain isolated from parameter access and diagnostic traffic.
Frequently Asked Questions about HCS01.1E-W0008-A-03-A-CC-EC-ET-SB-NN-FW:
Q: What cooling method is used by the HCS01.1E-W0008-A-03-A-CC-EC-ET-SB-NN-FW drive controller?
A: The HCS01.1E-W0008-A-03-A-CC-EC-ET-SB-NN-FW utilizes an integrated blower for internal air cooling.
Q: What is the device peak current rating of the HCS01.1E-W0008-A-03-A-CC-EC-ET-SB-NN-FW?
A: This controller has a peak output current of 8 A for supported applications.
Q: Which communication interface is available on the HCS01.1E-W0008-A-03-A-CC-EC-ET-SB-NN-FW controller?
A: The HCS01.1E-W0008-A-03-A-CC-EC-ET-SB-NN-FW is equipped with a SERCOS III master interface for cross communication.
Q: What mains voltage range does the HCS01.1E-W0008-A-03-A-CC-EC-ET-SB-NN-FW support?
A: This model can operate with mains voltages ranging from 200 V to 500 V AC, with a tolerance of plus or minus 10%.
Q: What is the IP rating of the HCS01.1E-W0008-A-03-A-CC-EC-ET-SB-NN-FW drive controller?
A: The drive controller is rated at IP20, providing basic protection against solid objects.