4.95 based on 202 reviews

🙶 Product was as advertised, got the machine back up and running at a fraction of OEM price. Delivered on ti... 🙷

HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW Bosch Rexroth Indramat

MPN: R911338267

No Tariffs On US Orders
  • Rated 4.5 (35 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships Fast

Current response time:
5 Minutes 8 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a SERCOS III master communication interface and supports MultiEthernet connections. The controller is cooled with internal air through an integrated blower, has a device peak current of 8 Amps, and is rated at IP20.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW is a compact drive controller produced by Bosch Rexroth Indramat in the HCS IndraDrive Controllers series. It combines power electronics, motion control, and fieldbus connectivity in one housing, making it suitable for low-power servo or induction motors used in packaging, handling, and assembly cells. The unit regulates torque, speed, and position so each axis follows commands from a supervisory PLC with precise timing during indexing, transport, and positioning tasks. Its compact format also helps when cabinet space is limited and several axes must be installed side by side.

For installation, the controller accepts three-phase power in a range of 3 x AC 200 to 500 V ±10%, which allows the same cabinet design to support several plant supplies. Its power stage can deliver a peak motor current of 8 A, and excess heat is removed by internal air cooling through an integrated blower. The enclosure has an IP20 rating, so it must be mounted inside a protected cabinet while remaining finger-safe. Motion data travel over a SERCOS III master link that supports cross communication between drives, while a dedicated Multi-Ethernet port handles PROFINET, EtherNet/IP, or EtherCAT traffic for higher-level control integration.

This variant uses the ADVANCED control section and is design version 1. Feedback enters through the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 port to provide high-resolution absolute position data for closed-loop operation. When a safety request occurs, the integrated STO (Safe Torque Off) circuit shuts down torque without mechanical relays. The power supply arrangement allows regenerated energy to flow to adjacent axes before dissipation, which can improve efficiency in multi-axis systems and reduce unnecessary heat buildup on shared installations.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
MultiEthernet
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0008A03ACCECETL3NNFW
  • HCS01 1E W0008 A 03 A CC EC ET L3 NN FW
  • hcs01.1e-w0006-a-02-a-cc-ec-pb-s4-nn-fw
  • HCS1.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW:

Q: What communication interface is provided on the HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW controller?

A: The HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW uses SERCOS III master for cross communication with other automation devices.

Q: What is the control section design type of the HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW model?

A: This drive controller is designed with an ADVANCED control section type, allowing for enhanced operational capabilities.

Q: How is the HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW controller cooled?

A: Cooling in this model is achieved using internal air circulation through an integrated blower.

Q: What is the acceptable mains voltage range for the HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW?

A: The controller can operate on a mains voltage range of 3 x AC 200 to 500 V with a tolerance of ±10%.

Q: What level of environmental protection does the HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW provide?

A: This unit features an IP20 rating, which means it offers protection against solid objects larger than 12.5 mm but is not protected against water.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW is an HCS drive controller with an ADVANCED control section. SERCOS III master cross communication and MultiEthernet support give the controller strong network flexibility for integrated motion platforms. STO and a 3 x AC 200...500 V ±10% mains range make safe, dependable operation a key advantage.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo