HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW Bosch Rexroth Indramat
MPN: R911338267
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
5 Minutes
8 Seconds
The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a SERCOS III master communication interface and supports MultiEthernet connections. The controller is cooled with internal air through an integrated blower, has a device peak current of 8 Amps, and is rated at IP20.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW is a compact drive controller produced by Bosch Rexroth Indramat in the HCS IndraDrive Controllers series. It combines power electronics, motion control, and fieldbus connectivity in one housing, making it suitable for low-power servo or induction motors used in packaging, handling, and assembly cells. The unit regulates torque, speed, and position so each axis follows commands from a supervisory PLC with precise timing during indexing, transport, and positioning tasks. Its compact format also helps when cabinet space is limited and several axes must be installed side by side.
For installation, the controller accepts three-phase power in a range of 3 x AC 200 to 500 V ±10%, which allows the same cabinet design to support several plant supplies. Its power stage can deliver a peak motor current of 8 A, and excess heat is removed by internal air cooling through an integrated blower. The enclosure has an IP20 rating, so it must be mounted inside a protected cabinet while remaining finger-safe. Motion data travel over a SERCOS III master link that supports cross communication between drives, while a dedicated Multi-Ethernet port handles PROFINET, EtherNet/IP, or EtherCAT traffic for higher-level control integration.
This variant uses the ADVANCED control section and is design version 1. Feedback enters through the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 port to provide high-resolution absolute position data for closed-loop operation. When a safety request occurs, the integrated STO (Safe Torque Off) circuit shuts down torque without mechanical relays. The power supply arrangement allows regenerated energy to flow to adjacent axes before dissipation, which can improve efficiency in multi-axis systems and reduce unnecessary heat buildup on shared installations.
Frequently Asked Questions about HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW:
Q: What communication interface is provided on the HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW controller?
A: The HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW uses SERCOS III master for cross communication with other automation devices.
Q: What is the control section design type of the HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW model?
A: This drive controller is designed with an ADVANCED control section type, allowing for enhanced operational capabilities.
Q: How is the HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW controller cooled?
A: Cooling in this model is achieved using internal air circulation through an integrated blower.
Q: What is the acceptable mains voltage range for the HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW?
A: The controller can operate on a mains voltage range of 3 x AC 200 to 500 V with a tolerance of ±10%.
Q: What level of environmental protection does the HCS01.1E-W0008-A-03-A-CC-EC-ET-L3-NN-FW provide?
A: This unit features an IP20 rating, which means it offers protection against solid objects larger than 12.5 mm but is not protected against water.