The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-A-CC-EC-EM-L3-NN-FW is part of the HCS IndraDrive Controllers series and features a peak device current of 8 Amps. It uses an internal air cooling method with an integrated blower and has IP20 rating. The drive controller comes equipped with a SERCOS III communication interface and supports IndraDyn Hiperface and EnDat 2.1/2.2 encoder types.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0008-A-03-A-CC-EC-EM-L3-NN-FW is a compact drive controller in the HCS IndraDrive Controllers series. It uses the HCS01 hardware format and converts cabinet mains power into regulated three-phase output for synchronous and induction motors. This allows the unit to support closed-loop torque, speed, and position control in equipment such as pick-and-place stations, indexing tables, and conveyor modules. Its plug-in architecture separates the power unit from the control section, which supports modular system design without changing field wiring.
The controller exchanges real-time motion data through a SERCOS III master (cross communication) link, allowing deterministic coordination of multiple axes. Its control electronics use the ADVANCED variant, which provides expanded processing capability for demanding motion tasks. Thermal energy is removed by internal air cooling through an integrated blower, so no external ducting is required in the cabinet. During acceleration, the inverter can supply a peak output of 8 A, which suits small and medium motor applications. The housing has an IP20 rating, so the unit is intended for installation inside clean electrical enclosures where dust and moisture are controlled.
The power section accepts utility feeds from 3 x AC 200…500 V ±10%, which supports operation on a wide range of industrial supply systems. Feedback handling includes a first channel for Encoder IndraDyn Hiperface/EnDat 2.1/2.2 signals and a second channel for Encoder emulation pulses used by external control equipment. Safety is supported by STO (Safe Torque Off), which disables gate signals to the IGBTs through hardware. The unit uses an infeeding and fed power supply concept within the HCS01 platform and is intended to operate with its designated control section in the modular drive architecture.
Frequently Asked Questions about HCS01.1E-W0008-A-03-A-CC-EC-EM-L3-NN-FW:
Q: What communication interface does the HCS01.1E-W0008-A-03-A-CC-EC-EM-L3-NN-FW support?
A: The HCS01.1E-W0008-A-03-A-CC-EC-EM-L3-NN-FW drive controller utilizes a SERCOS III master interface for cross communication.
Q: What is the cooling method for the HCS01.1E-W0008-A-03-A-CC-EC-EM-L3-NN-FW controller?
A: This model uses internal air cooling with an integrated blower for thermal management.
Q: What level of ingress protection does the HCS01.1E-W0008-A-03-A-CC-EC-EM-L3-NN-FW offer?
A: The HCS01.1E-W0008-A-03-A-CC-EC-EM-L3-NN-FW controller has an IP20 protection rating against solid objects larger than 12mm.
Q: What is the peak current capability of the HCS01.1E-W0008-A-03-A-CC-EC-EM-L3-NN-FW?
A: This drive controller delivers a device peak current of 8 A for brief high-load requirements.
Q: What safety feature is included with the HCS01.1E-W0008-A-03-A-CC-EC-EM-L3-NN-FW drive controller?
A: The main safety feature present is STO (Safe Torque Off), which disables the drive torque in the event of a fault.