4.95 based on 202 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

HCS01.1E-W0008-A-03-A-CC-EC-EC-NN-NN-FW Bosch Rexroth Indramat

MPN: R911343293

No Tariffs On US Orders
  • Rated 4.5 (66 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-A-CC-EC-EC-NN-NN-FW belongs to the HCS IndraDrive Controllers series and is an HCS drive controller with an IP20 rating. It features SERCOS III master cross communication, operates with a device peak current of 8 Amps, and supports input voltages from 200 to 500 Volts AC. The unit uses internal air cooling through an integrated blower and includes two encoder interfaces for IndraDyn Hiperface or EnDat 2.1/2.2.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-A-CC-EC-EC-NN-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It links industrial PLCs to individual motor axes and converts fieldbus commands into regulated torque, speed, and position control. By combining a power stage, encoder interfaces, and network communication in one housing, the unit helps reduce cabinet complexity and supports modular automation in packaging, printing, and material-handling equipment. This layout keeps motion control functions centralized at the axis while preserving straightforward integration with the rest of the machine.

It operates from a three-phase mains supply of 3 x AC 200…500 V ±10%, which allows the same unit to be used across a wide industrial voltage range. The power section can deliver up to 8 A of peak current for short acceleration demands, and heat is removed by internal air cooling with an integrated blower so no external fan assembly is required. The housing has an IP20 rating, which means the controller is intended for installation inside a protective cabinet, and motion data is exchanged through a SERCOS III master with cross communication interface to keep multiple axes synchronized during operation. Its infeeding and fed power supply arrangement allows regenerative energy from decelerating axes to be returned to the DC link, and two encoder sockets accept IndraDyn Hiperface or EnDat 2.1/2.2 signals for precise feedback handling.

The controller uses the ADVANCED control section, which adds processing capability for interpolation and electronic gearing. The unit is identified as Design Version 1, and it is not equipped with a safety interface, so functions such as STO or emergency-stop processing must be implemented outside the controller. This arrangement suits machines that place safety logic in separate hardware. The controller remains focused on axis regulation, communication, and feedback processing during normal machine operation.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0008A03ACCECECNNNNFW
  • HCS01 1E W0008 A 03 A CC EC EC NN NN FW
  • hcs01.1e-w0006-a-02-a-cc-ec-nn-s4-nn-fw
  • HCS1.1E-W0008-A-03-A-CC-EC-EC-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-A-CC-EC-EC-NN-NN-FW:

Q: What type of communication interface is provided on the HCS01.1E-W0008-A-03-A-CC-EC-EC-NN-NN-FW drive controller?

A: This drive controller is equipped with a SERCOS III master communication interface for cross communication.

Q: What cooling method does the HCS01.1E-W0008-A-03-A-CC-EC-EC-NN-NN-FW utilize?

A: An internal integrated blower is used for air cooling on this model.

Q: What is the device peak current supported by the HCS01.1E-W0008-A-03-A-CC-EC-EC-NN-NN-FW drive controller?

A: The HCS01.1E-W0008-A-03-A-CC-EC-EC-NN-NN-FW controller supports a device peak current of 8 A.

Q: What IP rating does the HCS01.1E-W0008-A-03-A-CC-EC-EC-NN-NN-FW feature?

A: This drive controller has an IP20 protection rating.

Q: What is the supported mains voltage range for the HCS01.1E-W0008-A-03-A-CC-EC-EC-NN-NN-FW?

A: The mains voltage range supported is 3 x AC 200 to 500 V with a ±10% tolerance.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-A-CC-EC-EC-NN-NN-FW is an HCS drive controller with ADVANCED control section architecture and internal air cooling through an integrated blower. SERCOS III master cross communication and 8 A peak current make the controller a highly capable choice for precise, responsive drive control.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo