4.95 based on 202 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

HCS01.1E-W0008-A-03-A-CC-EC-EC-L4-NN-FW Bosch Rexroth Indramat

MPN: R911343377

No Tariffs On US Orders
  • Rated 4.4 (41 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-A-CC-EC-EC-L4-NN-FW is a drive controller from the HCS IndraDrive Controllers series. This ADVANCED design features a device peak current of 8 Amps and an internal cooling system with an integrated blower. It includes SERCOS III master cross communication and supports STO and Safe Brake Control safety interfaces.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-A-CC-EC-EC-L4-NN-FW drive controller is produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. Designed for cabinet mounting in multi-axis automation, the unit governs power flow from the plant mains to synchronous or asynchronous motors while exchanging real-time motion data with higher-level control systems. By integrating power conversion, safety logic, and feedback processing into one housing, the controller supports coordinated speed, torque, and position control in production cells where compact installation and predictable axis response are important.

The controller accepts a three-phase supply of 3 x AC 200...500 V ±10% and can deliver up to 8 A of peak output current to the connected axis. Internal thermal management relies on internal air cooling, so an integrated blower moves cabinet air across the heat sinks without external ducting. Touch-safe construction is verified by the IP20 rating for installation inside a protected electrical enclosure. Both feedback channels use the IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, and motion commands with drive-to-drive data exchange are carried over the SERCOS III master with cross communication interface for synchronized operation.

The control section is the ADVANCED type, which provides expanded processing capability for electronic gearing, interpolation, and parameter storage. Integrated safety includes STO (Safe Torque Off) and SBC (Safe Brake Control), allowing the drive to support controlled shutdown functions without separate external contactors for these tasks. Energy is exchanged with the DC bus through DC-bus infeeding, which allows regenerated power to be shared among axes and can reduce the need for braking resistors. Design version 1 and the compact HCS01 mechanical frame support dense cabinet layouts while still leaving space for wiring and service access.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
  • HCS011EW0008A03ACCECECL4NNFW
  • HCS01 1E W0008 A 03 A CC EC EC L4 NN FW
  • hcs01.1e-w0006-a-02-a-cc-ec-nn-nn-nn-fw
  • HCS1.1E-W0008-A-03-A-CC-EC-EC-L4-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-A-CC-EC-EC-L4-NN-FW:

Q: What is the peak current rating for the HCS01.1E-W0008-A-03-A-CC-EC-EC-L4-NN-FW drive controller?

A: The HCS01.1E-W0008-A-03-A-CC-EC-EC-L4-NN-FW controller operates with a peak current of 8 A.

Q: How is the HCS01.1E-W0008-A-03-A-CC-EC-EC-L4-NN-FW cooled?

A: This drive controller uses internal air cooling via an integrated blower.

Q: Which communication interface does the HCS01.1E-W0008-A-03-A-CC-EC-EC-L4-NN-FW use?

A: The main communication interface for this controller is SERCOS III master with cross communication capability.

Q: What is the acceptable mains voltage range for the HCS01.1E-W0008-A-03-A-CC-EC-EC-L4-NN-FW?

A: Its mains voltage range is 3 x AC 200 to 500 V with a ±10% tolerance.

Q: What safety features are available on the HCS01.1E-W0008-A-03-A-CC-EC-EC-L4-NN-FW controller?

A: This controller features STO (Safe Torque Off) and SBC (Safe Brake Control) safety interfaces.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-A-CC-EC-EC-L4-NN-FW is an HCS drive controller with an ADVANCED control section that feels well suited for demanding motion control tasks. SERCOS III master cross communication and STO/SBC safety functions support clean network integration and dependable machine protection. Internal air cooling and 8 A peak current give this controller a very capable performance profile.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo