4.95 based on 202 reviews

🙶 Product was as advertised, got the machine back up and running at a fraction of OEM price. Delivered on ti... 🙷

HCS01.1E-W0008-A-03-A-CC-EC-CN-NN-NN-FW Bosch Rexroth Indramat

MPN: R911380329

No Tariffs On US Orders
  • Rated 4.5 (44 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-A-CC-EC-CN-NN-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features a SERCOS III master communication interface, an ADVANCED control section, and an internal air cooling method using an integrated blower. The device supports a peak current of 8 Amps, offers CANopen and encoder interfaces, and has an IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0008-A-03-A-CC-EC-CN-NN-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat and supplied in the HCS IndraDrive Controllers series. It serves as the power and communication interface between an IndraDrive power stage and connected servo or spindle motors, converting control commands into regulated torque and speed output for automated machinery. Feedback signals return through the controller so closed-loop motion remains coordinated during positioning, speed regulation, and other axis tasks. In packaging lines, machine tools, and transfer systems, it acts as the link between the control system and the motor-driven axis.

Incoming three-phase power can range from 3 x AC 200...500 V ±10%, allowing the unit to operate on many industrial power systems. During dynamic peaks, the power section can supply up to 8 A of output current, which limits the motor size that can be paired without derating. Thermal management uses an integrated internal air blower, which pushes cabinet air through the heat sink and removes the need for external ducting. The enclosure has an IP20 rating for finger-safe access, and motion commands are exchanged over SERCOS III master with cross communication for synchronized multi-drive operation. The controller is part of the HCS01 line and uses the compact 50 mm width frame, which helps it fit tightly spaced control cabinets.

For motor feedback, the control section supports an IndraDyn encoder with Hiperface or EnDat 2.1/2.2, giving the drive access to position data needed for precise axis control. Higher-level data exchange and diagnostics are available through CANopen on the second interface, which adds a separate communication path for integration with external control devices. The unit is assembled with the ADVANCED control section, so no additional option cards are required for standard positioning tasks, and BASIC control sections are not supported with this configuration. Energy exchange with the common DC bus uses an infeeding and fed topology, allowing regenerated braking energy from one axis to be shared with other connected axes. This setup is useful in multi-axis systems where one drive is decelerating while another is accelerating.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
8 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
CANopen
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0008A03ACCECCNNNNNFW
  • HCS01 1E W0008 A 03 A CC EC CN NN NN FW
  • hcs01.1e-w0006-a-02-a-cc-ec-et-s4-nn-fw
  • HCS1.1E-W0008-A-03-A-CC-EC-CN-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0008-A-03-A-CC-EC-CN-NN-NN-FW:

Q: What communication interface does the HCS01.1E-W0008-A-03-A-CC-EC-CN-NN-NN-FW use?

A: The HCS01.1E-W0008-A-03-A-CC-EC-CN-NN-NN-FW supports SERCOS III master cross communication for high-performance networking.

Q: What is the peak current capability of the HCS01.1E-W0008-A-03-A-CC-EC-CN-NN-NN-FW?

A: This drive controller provides a device peak current of 8 A.

Q: How is the HCS01.1E-W0008-A-03-A-CC-EC-CN-NN-NN-FW cooled during operation?

A: Cooling is achieved internally via an integrated blower using air.

Q: What is the required mains voltage for the HCS01.1E-W0008-A-03-A-CC-EC-CN-NN-NN-FW controller?

A: The HCS01.1E-W0008-A-03-A-CC-EC-CN-NN-NN-FW operates with a mains voltage supply of 3 x AC 200...500 V ±10%.

Q: What level of ingress protection does the HCS01.1E-W0008-A-03-A-CC-EC-CN-NN-NN-FW offer?

A: This model is built with an IP20 rating, providing a basic level of protection against solid objects.


Internal Product Review

  • ‘‘The HCS01.1E-W0008-A-03-A-CC-EC-CN-NN-NN-FW is an HCS drive controller with an ADVANCED control section that gives the platform a refined, high-performance control profile. SERCOS III master cross communication and CANopen support make the controller especially appealing for streamlined network integration in automated systems. Internal blower cooling and 8 A peak current support stable thermal behavior and confident drive response.’’