HCS01.1E-W0006-A-03-E-S3-EC-NN-NN-NN-FW Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0006-A-03-E-S3-EC-NN-NN-NN-FW is part of the HCS IndraDrive Controllers series and features a SERCOS III communication interface. This drive controller has a peak device current of 6 Amps and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1 or 2.2. It uses internal air cooling through an integrated blower and has an IP20 rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0006-A-03-E-S3-EC-NN-NN-NN-FW is a drive controller from Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. The device forms the power and control interface between plant mains and an IndraDyn motor, converting line energy into regulated three-phase output while exchanging real-time motion data with higher-level automation systems. By combining power conversion, sensor feedback processing, and fieldbus communication in one housing, it streamlines axis integration for packaging, handling, and general factory automation lines.
The converter accepts a three-phase mains supply of 3 x AC 200...500 V ±10%, allowing deployment on low- or medium-voltage plant power systems without external transformers. Its power section can deliver up to 6 A of peak output current, so it is sized for low-power servo axes, indexing tables, or auxiliary actuators. Motion commands and status words are exchanged over SERCOS III, giving deterministic Ethernet-based cycle times for synchronized multi-axis control. Thermal management relies on internal air cooling through an integrated blower, which draws cabinet air through the heat sink. An enclosure rating of IP20 means the unit must be mounted inside a protected electrical cabinet to avoid exposure to conductive dust or liquids.
The controller uses the ECONOMY control section, meaning parameter memory, I/O, and safety-related functions are reduced while motion control remains available. The unit is hardware revision 1. Power is received from an upstream supply in an infeeding/feeded arrangement, so the converter can share a common DC bus where braking energy is exchanged between axes. The drive core belongs to the HCS01 line, and the encoder interface supports IndraDyn Hiperface and EnDat feedback. A second feedback port is not equipped, and the safety interface is omitted, so external safe torque-off hardware is required when that function is needed.
Frequently Asked Questions about HCS01.1E-W0006-A-03-E-S3-EC-NN-NN-NN-FW:
Q: What communication interface is available on the HCS01.1E-W0006-A-03-E-S3-EC-NN-NN-NN-FW drive controller?
A: The HCS01.1E-W0006-A-03-E-S3-EC-NN-NN-NN-FW features a SERCOS III communication interface for real-time industrial networking.
Q: How is the HCS01.1E-W0006-A-03-E-S3-EC-NN-NN-NN-FW cooled?
A: This drive controller is cooled internally using an integrated blower for air circulation.
Q: What is the peak current output for the HCS01.1E-W0006-A-03-E-S3-EC-NN-NN-NN-FW?
A: The device is capable of delivering a peak current of 6 A to connected motors.
Q: What mains voltage range does the HCS01.1E-W0006-A-03-E-S3-EC-NN-NN-NN-FW support?
A: This model operates on a mains voltage range of 3 x AC 200...500 V with a tolerance of ±10%.
Q: Which encoder interface is available on the HCS01.1E-W0006-A-03-E-S3-EC-NN-NN-NN-FW drive controller?
A: The controller offers encoder support through its IndraDyn Hiperface and EnDat 2.1/2.2 interface.