The Bosch Rexroth Indramat HCS01.1E-W0006-A-02-E-S3-EC-NN-L4-AA-FW is part of the HCS IndraDrive Controllers series and features a SERCOS III communication interface and 6 Amp peak current. This controller is designed with internal air cooling through an integrated blower and provides IP20 protection. It includes STO and SBC safety interfaces and supports encoder interfaces like IndraDyn Hiperface and EnDat 2.1/2.2.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0006-A-02-E-S3-EC-NN-L4-AA-FW is a compact drive controller from Bosch Rexroth Indramat in the HCS IndraDrive Controllers series. It is used for closed-loop speed and torque control on low-power machine axes and is intended to operate with IndraDyn servomotors in systems that share a common DC bus. The unit belongs to the HCS01 line with design version 1, and its integrated network connection lets it exchange real-time motion commands and status data with higher-level control hardware. By regulating motor current in real time, it supports accurate response to changing load and speed commands during cyclic machine operation.
This controller accepts a three-phase supply of 3 × AC 110–230 V ±10% and can deliver a peak output of 6 A to the motor windings. Heat is removed by internal air cooling through an integrated blower, so the device does not require an external fan tray for normal cabinet installation. Its enclosure has an IP20 rating, which means it must be mounted inside a protected control cabinet. Motion and parameter data are transferred over SERCOS III, providing deterministic cyclic communication between the drive and the control system. The power section can also exchange regenerated energy with the shared DC bus during deceleration, which supports multi-axis operation.
The attached control section is the ECONOMY version and supports standard motion functions without adding unnecessary interface complexity. Position feedback is connected through the IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, while the second feedback channel remains unused to keep wiring simpler. Integrated safety includes STO (Safe Torque Off) and SBC (Safe Brake Control), allowing the drive to remove torque and control brake release through built-in safety functions. This layout is suitable for cabinet-mounted servo applications that need encoder-based feedback, networked motion control, and integrated safety functions in a compact housing.
Frequently Asked Questions about HCS01.1E-W0006-A-02-E-S3-EC-NN-L4-AA-FW:
Q: What communication interface does the HCS01.1E-W0006-A-02-E-S3-EC-NN-L4-AA-FW use?
A: The communication interface on this controller is SERCOS III.
Q: How is the HCS01.1E-W0006-A-02-E-S3-EC-NN-L4-AA-FW drive controller cooled?
A: This model features air cooling through an integrated blower.
Q: What is the peak current capability of the HCS01.1E-W0006-A-02-E-S3-EC-NN-L4-AA-FW?
A: The device supports a peak current of 6 A.
Q: What is the IP rating of the HCS01.1E-W0006-A-02-E-S3-EC-NN-L4-AA-FW drive controller?
A: The HCS01.1E-W0006-A-02-E-S3-EC-NN-L4-AA-FW has an IP20 protection rating.
Q: What safety features are included on the HCS01.1E-W0006-A-02-E-S3-EC-NN-L4-AA-FW controller?
A: The safety interface features STO (Safe Torque Off) and SBC (Safe Brake Control).