4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

HCS01.1E-W0006-A-02-B-ET-EC-EM-S4-NN-FW Bosch Rexroth Indramat

MPN: R911342379

No Tariffs On US Orders
  • Rated 4.4 (45 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0006-A-02-B-ET-EC-EM-S4-NN-FW is part of the HCS IndraDrive Controllers series and serves as a drive controller with an IP20 rating. It features a MultiEthernet communication interface, an internal air cooling system through an integrated blower, and a device peak current of 6 Amps. The controller supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2, and operates at a mains voltage of 3 x AC 110 to 230 Volts ±10%.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0006-A-02-B-ET-EC-EM-S4-NN-FW is a compact drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. Designed for cabinet installation, the unit coordinates motor current and velocity loops in small-to-medium automation axes, providing a programmable interface between the machine PLC and connected servomotors. By managing regulated power flow and closed-loop feedback, the controller simplifies motion tasks such as positioning, speed regulation, and synchronous operation in production lines and material-handling equipment.

Electrical input is accepted from a three-phase supply of 3 x AC 110...230 V ±10%, so the same model can be deployed worldwide on low-voltage mains without additional transformers. Internally, an integrated blower supports internal air cooling, moving heat away from semiconductor modules and helping stabilize thermal conditions inside the drive. The permissible instantaneous motor demand is capped at 6 A, a peak current that marks the controller's short-term overload point. For networked machines, the onboard communication port supports MultiEthernet, enabling parameter access over EtherNet/IP, PROFINET, or EtherCAT on a single connector. An enclosure classification of IP20 indicates that the unit must be mounted in a closed control cabinet to avoid accidental contact with live parts.

The controller is paired with a control section designated BASIC, which indicates a minimal function set for this model and matches design version 1 of the HCS01 line. Position feedback is accepted through the first encoder slot, which reads IndraDyn Hiperface/EnDat 2.1/2.2 encoder signals, while the second slot outputs encoder emulation pulses for downstream devices that need incremental references. DC bus energy is exchanged through an infeeding / fed power supply arrangement that supports common-bus systems, and no additional design options are fitted. Firmware is ordered separately so the hardware can be matched with an application-specific software feature set.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
6 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0006A02BETECEMS4NNFW
  • HCS01 1E W0006 A 02 B ET EC EM S4 NN FW
  • hcs01.1e-w0005-a-03-b-et-ec-nn-l4-nn-fw
  • HCS1.1E-W0006-A-02-B-ET-EC-EM-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0006-A-02-B-ET-EC-EM-S4-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0006-A-02-B-ET-EC-EM-S4-NN-FW feature?

A: The HCS01.1E-W0006-A-02-B-ET-EC-EM-S4-NN-FW supports MultiEthernet communication for industrial networking.

Q: What is the peak current output of the HCS01.1E-W0006-A-02-B-ET-EC-EM-S4-NN-FW IndraDrive controller?

A: This drive controller has a peak output current rating of 6 A.

Q: How is the HCS01.1E-W0006-A-02-B-ET-EC-EM-S4-NN-FW drive controller cooled?

A: The integrated blower provides internal air cooling for the HCS01.1E-W0006-A-02-B-ET-EC-EM-S4-NN-FW.

Q: What type of encoder connections does Interface 1 of the HCS01.1E-W0006-A-02-B-ET-EC-EM-S4-NN-FW support?

A: This model supports encoder connections via IndraDyn Hiperface or EnDat 2.1/2.2 on its first interface.

Q: What is the mains voltage requirement for the HCS01.1E-W0006-A-02-B-ET-EC-EM-S4-NN-FW drive controller?

A: The HCS01.1E-W0006-A-02-B-ET-EC-EM-S4-NN-FW operates at a mains voltage of 3 x AC 110 to 230 V with a ±10% tolerance.


Internal Product Review

  • ‘‘The HCS01.1E-W0006-A-02-B-ET-EC-EM-S4-NN-FW is an HCS drive controller featuring a BASIC control section and MultiEthernet communication. Internal blower cooling and a 6 A peak current give the controller efficient thermal performance and dependable drive response.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo