HCS01.1E-W0006-A-02-B-ET-EC-EM-L3-NN-FW Bosch Rexroth Indramat
MPN: R911341795
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0006-A-02-B-ET-EC-EM-L3-NN-FW is part of the HCS IndraDrive Controllers series and is classified as an HCS drive controller. It features a MultiEthernet communication interface, supports encoder interfaces including IndraDyn Hiperface and EnDat 2.1 and 2.2, and delivers a device peak current of 6 Amps. The controller uses internal air cooling through an integrated blower and provides an IP20 protection rating with a mains voltage range of 3 x AC 110 to 230 Volts.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0006-A-02-B-ET-EC-EM-L3-NN-FW drive controller is produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It conditions incoming line power, processes feedback, and issues precisely timed current so connected servo or induction motors follow PLC motion commands. By combining power electronics and control logic in a compact housing, it supports material-handling, packaging, and light-assembly machines that benefit from distributed drive architecture.
Field communication is handled through MultiEthernet, allowing the same hardware to join EtherNet/IP, PROFINET, or EtherCAT networks without option cards. The power section accepts a mains range of 3 x AC 110...230 V ±10%, which suits low-voltage three-phase supplies common in small automation cells. During acceleration or short overloads, it can source up to 6 A of device peak current, giving adequate torque headroom while keeping the continuous rating modest. Thermal energy is removed by internal air cooling, and an integrated blower forces cabinet air across the heat sink without external ducts. With an enclosure classification of IP20, the unit must be installed inside a cabinet that provides the required protection against contact and contaminants.
The control section is the BASIC type, supplying standard motion functions without the advanced technology options used in higher tiers. Feedback connectivity includes a primary port for Encoder IndraDyn Hiperface/EnDat 2.1/2.2 signals and a secondary channel that outputs encoder emulation pulses for legacy control loops or diagnostic monitoring. Machine safety is addressed by the integrated STO interface, which removes drive torque through solid-state logic rather than mechanical contactors. The unit uses design version 1 and an infeeding or feeder power topology, which fits compact drive arrangements that need integrated control, feedback handling, and network communication in one housing.
Frequently Asked Questions about HCS01.1E-W0006-A-02-B-ET-EC-EM-L3-NN-FW:
Q: What communication interface is available on the HCS01.1E-W0006-A-02-B-ET-EC-EM-L3-NN-FW controller?
A: This model supports MultiEthernet as its communication interface.
Q: What is the peak current output of the HCS01.1E-W0006-A-02-B-ET-EC-EM-L3-NN-FW drive controller?
A: The HCS01.1E-W0006-A-02-B-ET-EC-EM-L3-NN-FW provides a device peak current of 6 A.
Q: How is the HCS01.1E-W0006-A-02-B-ET-EC-EM-L3-NN-FW cooled during operation?
A: Cooling is performed internally using an integrated blower with air cooling.
Q: What mains voltage does the HCS01.1E-W0006-A-02-B-ET-EC-EM-L3-NN-FW operate on?
A: The main voltage requirement for this model is 3 x AC 110 to 230 V ±10%.
Q: What safety interface is included with the HCS01.1E-W0006-A-02-B-ET-EC-EM-L3-NN-FW drive controller?
A: This controller offers an STO (Safe Torque Off) safety interface for secure motor shutdown.