HCS01.1E-W0006-A-02-B-ET-EC-EC-L4-NN-FW Bosch Rexroth Indramat
MPN: R911331616
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0006-A-02-B-ET-EC-EC-L4-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller features a MultiEthernet communication interface and supports a mains voltage of 3 x AC 110 to 230 volts. It offers an IP20 rating, internal air cooling with an integrated blower, and encoder interfaces for IndraDyn Hiperface or EnDat 2.1/2.2.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0006-A-02-B-ET-EC-EC-L4-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It serves as the power and regulation stage between a higher-level PLC and compatible synchronous or asynchronous motors, managing controlled speed, torque, and motion response in automated machinery. In operation, it converts incoming electrical power into regulated motor output while processing control commands from the automation system. The unit is intended for applications such as conveyors, handling systems, packaging equipment, and general industrial axes where compact drive integration and closed-loop motor control are required.
This controller communicates with upper-level equipment over MultiEthernet, allowing it to connect through supported Ethernet-based automation networks without separate option cards. It operates from a three-phase supply of 3 x AC 110...230 V ±10% and can provide a peak current of 6 A during short demand changes such as acceleration or transient load increases during axis motion. The housing has an IP20 enclosure rating, so it is intended for installation inside a protected cabinet. Heat is removed by internal air cooling through an integrated blower, which supports stable internal temperature control without external air ducts.
The control section uses the BASIC variant, which provides standard motion functions for routine drive tasks. The unit is design version 1 and includes STO and SBC safety functions for safe torque disable and coordinated brake control. Two encoder ports support IndraDyn Hiperface/EnDat 2.1/2.2 feedback signals, allowing connection to compatible high-resolution motor feedback devices for accurate position and speed evaluation. The power stage also supports infeeding and fed-drive operation so regenerated energy can be returned to the DC bus during deceleration.
Frequently Asked Questions about HCS01.1E-W0006-A-02-B-ET-EC-EC-L4-NN-FW:
Q: What communication interface is available on the HCS01.1E-W0006-A-02-B-ET-EC-EC-L4-NN-FW controller?
A: The HCS01.1E-W0006-A-02-B-ET-EC-EC-L4-NN-FW supports MultiEthernet for communication.
Q: How is the HCS01.1E-W0006-A-02-B-ET-EC-EC-L4-NN-FW controller cooled?
A: Cooling is achieved via an internal air system that uses an integrated blower.
Q: What is the peak current capability of the HCS01.1E-W0006-A-02-B-ET-EC-EC-L4-NN-FW controller?
A: This model provides a device peak current of 6 A.
Q: What mains voltage range does the HCS01.1E-W0006-A-02-B-ET-EC-EC-L4-NN-FW operate on?
A: The mains voltage for this controller is specified as 3 x AC 110 to 230 V ±10%.
Q: What safety interfaces are integrated in the HCS01.1E-W0006-A-02-B-ET-EC-EC-L4-NN-FW?
A: STO (Safe Torque Off) and SBC (Safe Brake Control) are included as safety interfaces.