4.95 based on 202 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW Bosch Rexroth Indramat

MPN: R911382250

No Tariffs On US Orders
  • Rated 4.5 (43 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface and supports encoder interfaces like IndraDyn Hiperface and EnDat 2.1 and 2.2. The unit operates at a mains voltage of 3 x AC 110 to 230 V and offers internal air cooling through an integrated blower.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW drive controller is built by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It serves as the power and control stage between a plant PLC and its servo or induction motors, supplying regulated current and voltage so automated axes can follow motion profiles with repeatability. Installed in a control cabinet, the unit supports coordinated positioning, speed control, and torque control across multiple axes in compact industrial equipment.

The drive has a peak output of 6 A, which provides short-term current headroom during rapid acceleration cycles. It accepts a three-phase supply of 3 x AC 110…230 V ±10%, allowing it to operate from low-voltage distribution networks without an autotransformer. Heat is removed by internal air cooling through an integrated blower, so no external cooling plate is required. The housing is rated IP20, which suits installation inside switchgear enclosures where protection against accidental contact and solid contaminants is needed, but water sealing is not required. Command and diagnostic data pass through the MultiEthernet port, giving access to real-time fieldbus systems such as EtherCAT, Ethernet/IP, and PROFINET without additional hardware.

Drive inhibit is handled through the STO interface, which removes torque-producing energy within the power stage without opening the mains circuit. Position feedback is accepted through the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 input, allowing compatibility with several common motor feedback formats. A second feedback channel is not equipped, which keeps the interface arrangement simple. The integrated supply supports infeeding and DC-bus-fed operation, so the device can source or absorb energy when used with adjacent axes on the shared DC bus. This controller belongs to the HCS01 line and is intended for use with a BASIC control section.

Communication Interface
MultiEthernet
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
6 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0006A02AETECNNL3NNFW
  • HCS01 1E W0006 A 02 A ET EC NN L3 NN FW
  • hcs01.1e-w0005-a-03-b-et-ec-ec-l3-nn-fw
  • HCS1.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW offer?

A: This drive controller is equipped with a MultiEthernet communication interface for versatile connectivity.

Q: How is the HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW cooled?

A: The HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW uses an internal air cooling method with an integrated blower.

Q: What is the peak current capacity of the HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW controller?

A: This unit can support a device peak current of 6 A for demanding applications.

Q: What mains voltage input does the HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW require?

A: The main power supply accepts 3-phase AC voltage from 110 to 230 V with a tolerance of ±10%.

Q: What safety interface is included with the HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW?

A: The safety interface features STO (Safe Torque Off) for secure operation.


Internal Product Review

  • ‘‘HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW is an HCS drive controller with MultiEthernet communication and internal air cooling through an integrated blower. Three-phase 110 to 230 V AC input and STO Safe Torque Off support make the unit a strong fit for compact automation axes.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo