HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW Bosch Rexroth Indramat
MPN: R911382250
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface and supports encoder interfaces like IndraDyn Hiperface and EnDat 2.1 and 2.2. The unit operates at a mains voltage of 3 x AC 110 to 230 V and offers internal air cooling through an integrated blower.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW drive controller is built by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It serves as the power and control stage between a plant PLC and its servo or induction motors, supplying regulated current and voltage so automated axes can follow motion profiles with repeatability. Installed in a control cabinet, the unit supports coordinated positioning, speed control, and torque control across multiple axes in compact industrial equipment.
The drive has a peak output of 6 A, which provides short-term current headroom during rapid acceleration cycles. It accepts a three-phase supply of 3 x AC 110…230 V ±10%, allowing it to operate from low-voltage distribution networks without an autotransformer. Heat is removed by internal air cooling through an integrated blower, so no external cooling plate is required. The housing is rated IP20, which suits installation inside switchgear enclosures where protection against accidental contact and solid contaminants is needed, but water sealing is not required. Command and diagnostic data pass through the MultiEthernet port, giving access to real-time fieldbus systems such as EtherCAT, Ethernet/IP, and PROFINET without additional hardware.
Drive inhibit is handled through the STO interface, which removes torque-producing energy within the power stage without opening the mains circuit. Position feedback is accepted through the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 input, allowing compatibility with several common motor feedback formats. A second feedback channel is not equipped, which keeps the interface arrangement simple. The integrated supply supports infeeding and DC-bus-fed operation, so the device can source or absorb energy when used with adjacent axes on the shared DC bus. This controller belongs to the HCS01 line and is intended for use with a BASIC control section.
Frequently Asked Questions about HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW:
Q: What type of communication interface does the HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW offer?
A: This drive controller is equipped with a MultiEthernet communication interface for versatile connectivity.
Q: How is the HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW cooled?
A: The HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW uses an internal air cooling method with an integrated blower.
Q: What is the peak current capacity of the HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW controller?
A: This unit can support a device peak current of 6 A for demanding applications.
Q: What mains voltage input does the HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW require?
A: The main power supply accepts 3-phase AC voltage from 110 to 230 V with a tolerance of ±10%.
Q: What safety interface is included with the HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW?
A: The safety interface features STO (Safe Torque Off) for secure operation.