4.95 based on 202 reviews

🙶 a+ fast delivery 🙷

HCS01.1E-W0006-A-02-A-CC-EC-EC-NN-NN-FW Bosch Rexroth Indramat

MPN: R911347061

No Tariffs On US Orders
  • Rated 4.5 (17 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0006-A-02-A-CC-EC-EC-NN-NN-FW is an HCS Drive Controller and part of the HCS IndraDrive Controllers series. The controller supports a SERCOS III master communication interface and features an internal air cooling method with integrated blower. It has a device peak current of 6 Amps and is rated for 3-phase AC voltages from 110 to 230 Volts with IP20 protection.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0006-A-02-A-CC-EC-EC-NN-NN-FW is a compact drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. Designed for small to medium axis drives, the unit manages power conversion and closed-loop regulation for synchronous and induction motors in automated machinery. It belongs to the HCS01 line and supports modular control sections for motion tasks that require precise velocity and position control on low-voltage three-phase mains. During operation, it coordinates motor current and feedback signals so commanded movement remains stable during starts, stops, and speed changes.

For supply, the controller accepts 3 x AC 110 to 230 V ±10%, allowing direct connection to low-voltage three-phase networks commonly found in assembly cells. Its device peak current reaches 6 A, providing headroom for short acceleration bursts without oversizing the inverter. The housing has an IP20 rating, so installation inside a control cabinet is required to protect the unit from accidental contact and solid contaminants. Thermal management relies on internal air cooling through an integrated blower, which circulates cabinet air through the heat sink without external ducting. Energy is exchanged with the DC bus through an infeeding and feeding topology, enabling common-bus operation with several axes on one supply section.

Motion commands and diagnostics move over a SERCOS III master channel that also handles cross-communication between drives. Both feedback ports are factory wired for Encoder IndraDyn Hiperface/EnDat 2.1/2.2, letting the controller read high-resolution position data from a wide range of compatible motors. This arrangement supports feedback flexibility when different motor families are used on related machine axes. The mounted control section is the ADVANCED variant, and the controller is design version 1. The unit does not include an integrated safety interface, so any required safety-related power interruption must be handled by external equipment.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
6 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0006A02ACCECECNNNNFW
  • HCS01 1E W0006 A 02 A CC EC EC NN NN FW
  • hcs01.1e-w0005-a-03-a-cc-ec-nn-l3-nn-fw
  • HCS1.1E-W0006-A-02-A-CC-EC-EC-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0006-A-02-A-CC-EC-EC-NN-NN-FW:

Q: What is the peak current capability of the HCS01.1E-W0006-A-02-A-CC-EC-EC-NN-NN-FW drive controller?

A: This drive controller provides a device peak current of 6 A for dependable motor operation.

Q: Which communication interface is provided on the HCS01.1E-W0006-A-02-A-CC-EC-EC-NN-NN-FW controller?

A: The HCS01.1E-W0006-A-02-A-CC-EC-EC-NN-NN-FW uses the SERCOS III master interface with cross communication for connectivity.

Q: How is the HCS01.1E-W0006-A-02-A-CC-EC-EC-NN-NN-FW controller cooled?

A: Cooling is managed internally using an integrated blower for efficient temperature regulation.

Q: What is the IP rating of the HCS01.1E-W0006-A-02-A-CC-EC-EC-NN-NN-FW drive controller?

A: This model has an IP20 rating, offering basic protection against solid objects over 12 mm but no liquid resistance.

Q: What design type is the control section of the HCS01.1E-W0006-A-02-A-CC-EC-EC-NN-NN-FW controller?

A: The control section of this controller is designed as 'ADVANCED', supporting enhanced features and flexibility.


Internal Product Review

  • ‘‘The HCS01.1E-W0006-A-02-A-CC-EC-EC-NN-NN-FW is an HCS Drive Controller with an ADVANCED control section and SERCOS III master communication. Internal air cooling through an integrated blower supports stable thermal management, and the 6 A peak current fits light to moderate servo applications. IP20 protection makes the controller a strong choice for enclosed IndraDrive installations.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo