The Bosch Rexroth Indramat HCS01.1E-W0006-A-02 is a drive controller from the HCS IndraDrive Controllers series. It features a peak current of 6 Amps and uses an internal air cooling method with an integrated blower. The controller supports a mains voltage of 3 x AC 110 to 230 Volts and has an IP20 rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0006-A-02 is a drive controller manufactured by Bosch Rexroth Indramat as part of the HCS IndraDrive Controllers series. It conditions three-phase mains power, generates regulated motor currents, and exchanges control signals with PLCs to run single-axis or multi-axis automation equipment. By integrating current regulation, protective monitoring, and communication functions into a narrow housing, the unit supports compact machine layouts in material-handling, packaging, and light machining applications.
An internal blower channels plant air across the heat sinks, so the cooling method is internal air cooling through an integrated blower, which avoids external ducting and maintains forced convection inside the control cabinet. The controller accepts a mains input of 3 x AC 110–230 V ±10%, enabling operation on low-voltage factory networks worldwide. During dynamic events, the power stage can deliver a device peak current of 6 A, giving overhead for torque surges on light mechanical loads. The enclosure has a rating of IP20, which guards against finger contact and larger objects, but the unit must be mounted in a sealed panel. The unit is Design Version 1, indicating the first functional release.
Within the HCS01 line, the controller uses an infeeding and feeding topology, so the DC bus can receive energy from a shared supply module or return power during braking. This allows several axes in the HCS IndraDrive Controllers series to share a common regenerative circuit and exchange energy across the DC bus during changing load conditions. Parameter sets and diagnostics follow established IndraDrive conventions, so the unit integrates predictably with IndraWorks, fieldbus nodes, and safety options. The shared bus arrangement supports coordinated axis groups where one motor is braking while another is accelerating.
Frequently Asked Questions about HCS01.1E-W0006-A-02:
Q: What cooling method is used in the HCS01.1E-W0006-A-02 drive controller?
A: The HCS01.1E-W0006-A-02 features internal air cooling using an integrated blower.
Q: What is the peak current specification of the HCS01.1E-W0006-A-02?
A: This model has a device peak current of 6 A.
Q: What is the mains voltage range for the HCS01.1E-W0006-A-02 controller?
A: The HCS01.1E-W0006-A-02 operates on a mains voltage of 3 x AC 110 to 230 V with a ±10% tolerance.
Q: What IP rating does the HCS01.1E-W0006-A-02 provide?
A: This controller offers an IP20 rating, indicating basic protection against solid objects greater than 12.5 mm.
Q: What is the design version of the HCS01.1E-W0006-A-02 drive controller?
A: The HCS01.1E-W0006-A-02 is a Design Version 1 unit.