The Bosch Rexroth Indramat HCS01.1E-W0005-A-03-B-ET-EC-PB-S4-NN-FW is a drive controller from the HCS IndraDrive Controllers series. This controller features a MultiEthernet communication interface, supports encoder types such as IndraDyn Hiperface and EnDat 2.1/2.2, and also includes a PROFIBUS interface. It uses internal air cooling through an integrated blower, is rated for a peak current of 5 Amps, and has an IP20 protection rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0005-A-03-B-ET-EC-PB-S4-NN-FW is a Bosch Rexroth Indramat drive controller in the HCS IndraDrive Controllers series. It combines power conversion with axis control so that servo or induction motors receive precisely timed voltage and current profiles for positioning, synchronized transport, or speed-regulated duties in automated machinery. The unit works with a separate control section, creating a modular platform that supports scalable performance while keeping cabinet depth consistent and preserving a familiar wiring layout across related axes. This separation of power and control functions also allows the drive platform to be adapted to different axis tasks without changing the main power stage.

The controller operates from a 3 x AC 200...500 V ±10% supply and can deliver up to 5 A of peak output, making it suitable for low-power handling axes and conveyor feeders. Heat generated by the IGBTs is removed through internal air cooling, using an integrated blower that helps limit external cabinet airflow requirements. The enclosure has an IP20 rating for protection against accidental contact, so the unit is intended for installation in closed control panels. Motion and diagnostic data are exchanged over a MultiEthernet port that supports several protocol variants without additional option cards. The unit is hardware revision 1, indicating the first design release for this model.

The control side of the power stage uses an Encoder IndraDyn Hiperface/EnDat 2.1/2.2 feedback channel for position loops and a PROFIBUS fieldbus interface for legacy PLC integration. Its control section is BASIC, indicating the standard feature set for this model. The power supply topology is infeeding/fed operation, allowing the device to share a common DC bus with regenerative drives. This combination allows closed-loop motor control on the feedback side while supporting established plant communication on the fieldbus side.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
5 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
PROFIBUS
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0005A03BETECPBS4NNFW
  • HCS01 1E W0005 A 03 B ET EC PB S4 NN FW
  • hcs01.1e-w0003-a-02-e-s3-ec-nn-nn-nn-fw
  • HCS1.1E-W0005-A-03-B-ET-EC-PB-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0005-A-03-B-ET-EC-PB-S4-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0005-A-03-B-ET-EC-PB-S4-NN-FW support?

A: The HCS01.1E-W0005-A-03-B-ET-EC-PB-S4-NN-FW supports MultiEthernet as its communication interface.

Q: What is the device peak current for the HCS01.1E-W0005-A-03-B-ET-EC-PB-S4-NN-FW?

A: This controller offers a device peak current rating of 5 A.

Q: How is the HCS01.1E-W0005-A-03-B-ET-EC-PB-S4-NN-FW cooled during operation?

A: The HCS01.1E-W0005-A-03-B-ET-EC-PB-S4-NN-FW uses air cooling with an internal integrated blower.

Q: What is the IP protection rating of the HCS01.1E-W0005-A-03-B-ET-EC-PB-S4-NN-FW?

A: The controller has an IP20 rating for its level of protection.

Q: What mains voltage supply does the HCS01.1E-W0005-A-03-B-ET-EC-PB-S4-NN-FW require?

A: This model is compatible with a mains voltage supply of 3 x AC 200...500 V ±10%.